B224BI: Isolator base for low-profile detectors. See DN- CA-2: Chassis for FACP control panel when DVC-EM is used <br /> 60054. with firefighter's telephone. Mounts in the top two rows of a <br /> B210LP: Low-profile base. Standard U.S. style. Replaces CAB-4 series enclosure. <br /> B710LP. See DN-60054. DP-DISP: Dress panel for top row in cabinet with CPU2- <br /> B501:European-style,4" (10.16 cm)base.See DN-60054. 3030D installed. <br /> B200S: Intelligent programmable sounder base, capable of DP-1B: Blank dress panel. Provides dead front panel for <br /> producing a variety of tone patterns including ANSI Temporal unused tiers; covers DAA2/DAX series or AA series amplifier. <br /> 3.Compatible with sychronization protocol. See DN-60054. See DN 7046. <br /> B200SCOA: Based on B200SA, with added CO detector CHS-BH1: Battery chassis; holds two 12.0 AH batteries. <br /> markings in English/French. For Canadian applications only. Mounts on the left side of DAA2 chassis.See DN 7046. <br /> B200SR: Sounder base, Temporal 3 or Continuous tone. See CA-1:Chassis,occupies one tier of a CAB-4 Series enclosure. <br /> DN-60054. The left side accommodates one DVC-EM and a DVC-KD <br /> (optional); and the right side houses a CMIC-1 microphone <br /> FMM-1: FlashScan monitor module.See DN-6720. and its well(optional). See DN-7045. <br /> FDM-1: FlashScan dual monitor module. See DN-6720. CA-2:Chassis assembly,occupies two tiers of a CAB-4 Series <br /> FZM-1:FlashScan two-wire detector monitor module.See DN- enclosure.The left side accommodates one DVC-EM mounted <br /> 6720. on a half-chassis and one NFS2-3030 or NCA-2 mounted on a <br /> half-chassis. The right side houses a microphone/handset <br /> FMM-101: FlashScan miniature monitor module. See DN- well.The CA-2 assembly includes CMIC-1 microphone.ADDR <br /> 6720. Series doors with two-tier visibility are available for use with <br /> FMM-4-20: FlashScan 4-20 mA protocol monitor module. See the CA-2 configuration: ADDR-B4, ADDR-C4, ADDR-D4 <br /> DN-60411. (below). <br /> FCM-1: FlashScan control module. See DN-6724. ADDR-B4:Two-tier-sized door designed for use with the CA-2 <br /> FCM-I-REL: FlashScan releasing control module. See DN- chassis configuration. ADDR Series doors are similar to CAB <br /> 60390. 4 Series "DR" doors, but a clear window space exposes the <br /> top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox <br /> FTM-1: Firephone Telephone Module connects a remote fire- with the ADDR-B4. See DN-7045, DN-6857. <br /> fighter telephone to a centralized telephone console. Reports ADDR-C4:Three-tier-sized door designed for use with the CA- <br /> status to panel. Wiring to jacks and handsets is supervised. 2 chassis configuration. ADDR Series doors are similar to <br /> See DN 6989. CAB-4 Series"DR"doors, but a clear window space exposes <br /> FRM-1: FlashScan relay module. See DN-6724. the top two tiers of the CAB-4 enclosure. Use an SBB-C4 <br /> FDRM-1: FlashScan dual monitor/dual relay module. See DN- backbox with the ADDR-C4.See DN-7045,DN-6857. <br /> 60709. ADDR-D4: Four-tier-sized door designed for use with the CA-2 <br /> NBG-12LX: Manual pull station,addressable. See DN-6726. chassis configuration.ADDR Series doors are similar to CAB- <br /> 4ISO-X: Isolator module.See DN 2243. Series "DR" doors, but a clear window space exposes the <br /> top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox <br /> XP6-C: FlashScan six-circuit supervised control module. See with the ADDR-D4. See DN-7045, DN-6857. <br /> DN-6924. DPA-1: Dress panel, used with the CA-1 chassis when config- <br /> XP6-MA: FlashScan six-zone interface module; connects ured with a DVC-EM, DVC-KD,and CMIC-1. See DN-7045. <br /> intelligent alarm system to two-wire conventional detection DPA-2:Dress Panel used with the CA-2 chassis assembly. <br /> zone.See DN-6925. <br /> FlashScan six-relay (Form-C) control module. See DPA-1A4: Dress panel, used with the CA-1 chassis when the <br /> XP6-R: <br /> . CMIC-1 is not used. Provides mounting options on right two <br /> bays for two ACS annunciators, or for blank plates. See DN- <br /> XP10-M: FlashScan ten-input monitor module. See DN-6923. 7045. <br /> SLC-IM: SLC integration module, for VESDAnet detectors. ADP-4B: Annunciator dress plate. Mounts in rows 2,3 or 4 of <br /> See DN-60755. a CAB-4 series enclosure. Used with ACS series annuncia- <br /> tors. <br /> ENCLOSURES,CHASSIS,AND DRESS PLATES <br /> CAB-4 Series Enclosure: NFS2-3030 mounts in a standard BMP-1: Blank module for unused module positions. <br /> CAB-4 Series enclosure (available in four sizes, "A" through DP-1B: Blank dress panel. Provides dead-front panel for <br /> "D"). Backbox and door ordered separately; requires BP2-4 unused tiers;covers DAA2/DAX series or AA-series amplifier. <br /> battery plate. A trim ring option is available for semi-flush BP2-4:Battery plate, required. <br /> mounting.See DN-6857. <br /> CHS-4L: Low-profile four-position Chassis.Mounts two AA-30 <br /> EQ Series Cabinets:EQ series cabinets will house amplifiers, amplifiers. <br /> power supplies, battery chargers and control modules. EQ <br /> cabinets are available in three sizes,"B"through"D". See DN- CHS-4N:Chassis for mounting up to four APS-6Rs. <br /> 60229. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. <br /> CAB-BM Marine System: Protects equipment in shipboard Mounts up to six modules in any CAB-4 series row. <br /> and waterfront applications. Order CPU2-3030D-M; for non- BB-100: Backbox for batteries and power supplies. The BB- <br /> English marine applications order CPU2-3030D and appropri- 100 is used to mount up to two 100 AH batteries and power <br /> ate KP-KIT-XX. Also order BB-MB for systems using 100 AH supply, if needed.30" (76.20 cm)wide x 25"(63.50 cm)high x <br /> batteries.For a full list of required and optional equipment,see 7.5"(19.05 cm)deep;depth includes door. <br /> DN 60688. BB-200: Backbox for batteries and power supplies. Holds up <br /> CHS-M3: Mounting chassis for CPU2-3030. One required for to four 100 AH batteries(200 AH capacity) and power supply. <br /> each CPU2-3030D/3030ND. <br /> Page 6 of 8-DN-7070:K•12/20/2013 <br />