30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) -CPU2-3030ND board:0.120 A. <br /> deep;depth includes door. -LCM-320:0.130 A. <br /> NFS-LBB: Battery Box.The NFS-LBB is used to mount up to -LEM-320:0.100 A. <br /> two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x -AMPS-24(E)":0.13 A. <br /> 14"(356 mm)high x 7.75"(197 mm)deep. Door:24.125"(613 (Draws power from secondary power source only.) <br /> mm)wide x 14.25"(362 mm)high;door adds 0.0625"(approx. NOTE: See AMPS-24(E) Manual 51907 for a complete current <br /> 1.6 mm)to depth. draw calculation sheet and details of input and output values. <br /> BB-UZC: Backbox for housing the UZC-256 for applications Battery charger range:7 AH-200 AH.Use separate cabinet <br /> where the UZC will not fit in panel enclosure. Black; for red, for batteries over 26 AH. <br /> order BB-UZC-R.See DN-3404. <br /> SEISKIT CAB: Seismic mounting kit. Required for seismic- Float Rate:27.6 V. <br /> certified applications with NFS2-3030 and other equipment SHIPPING WEIGHT <br /> mounted in CAB-4 Series Enclosures.Includes battery bracket • CPU2-3030D:5.95 lb(2.70 kg). <br /> for two 26 AH batteries. <br /> • <br /> SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery CPU2 3030ND:2.90 lb(1.32 kg). <br /> bracket for two 55 AH batteries. TEMPERATURE AND HUMIDITY RANGES <br /> OTHER OPTIONS This system meets NFPA requirements for operation at 0 - <br /> 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH <br /> 411:Slave digital alarm communicator.See DN-6619. (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the <br /> 411UDAC:Digital alarm communicator.See DN-6746. useful life of the system's standby batteries and the electronic <br /> IPDACT-2, IPDACT Internet Monitoring Module: Connects components may be adversely affected by extreme tempera <br /> to primary and secondary DACT telephone output ports for ture ranges and humidity. Therefore, it is recommended that <br /> internet communications over customer-provided Ethernet this system and its peripherals be installed in an environment <br /> connection. Requires compatible Teldat VisorALARM Central with a normal room temperature of 15-27°C/60-80°F. <br /> Station Receiver.Can use DHCP or static IP.See DN-60408. AGENCY LISTINGS AND APPROVALS <br /> IPCHSKIT: IP Communicator Chassis Mounting Kit. For These listings and approvals apply to the modules specified in <br /> mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 this document.In some cases,certain modules or applications <br /> series chassis. Use IPENC for external mounting applications. may not be listed by certain approval agencies, or listing may <br /> IPSPLT:Y-adapter option allow connection of both panel dialer be in process.Consult factory for latest listing status. <br /> outputs to one IPDACT-2/2UD cable input. • UL Listed:S635. <br /> IPENC: External enclosure for IPDACT, includes IPBRKT • ULC Listed:S635. <br /> mounting bracket; Red;for black,order IPENC-B. • MEA:232-06-E. <br /> IPGSM-4G:Internet and Digital Cellular Fire Alarm Communica- • FDNY:COA#6114. <br /> tor. Provides selectable configurable paths:cellular only,IP only, • CSFM:7165-0028:0224(Commercial). <br /> or IP primary with cellular backup.Connects to the primary and <br /> secondary ports of a DACT. For Canadian applications order • FM Approved. <br /> IPGSM-4GC.See DH-60769. • FM6320 Approved.Class 6320 for Gas Detection. <br /> NOTE:For other options including compatibility with retrofit equip- • City of Chicago. <br /> ment,refer to the panel's installation manual,the SLC manual,and • City of Denver. <br /> the Device Compatibility Document. • Singapore Productivity and Standards Board(PSB). <br /> System Specifications • CCCF listed. <br /> • Fire Services Department(Hong Kong). <br /> SYSTEM CAPACITY Marine Applications: Marine approved systems must be con- <br /> • Intelligent Signaling Line Circuits 1 expandable to 10 figured using components itemized in this document. (See <br /> • Intelligent detectors 159 per loop Main System Components,in"Product Line Information.)Spe- <br /> • Addressable monitor/control modules 159 per loop cific connections and requirements for those components are <br /> described in the installation document, PN 54756.When these <br /> • Programmable software zones over 2000 requirements are followed, systems are approved by the fol- <br /> • ACS annunciators lowing agencies: <br /> per CPU2-3030 32 address x 64 or 96 points • US Coast Guard 161.002/55/0 (Standard 46 CFR and <br /> NOTE: The CPU2-3030 can support up to 96 annunciator 161.002). <br /> address points perACM-24AT/-48A. • Lloyd's Register 11/600013(ENV 3 category). <br /> SPECIFICATIONS • American Bureau of Shipping(ABS)Type Approval. <br /> Primary Input Power: NOTE:For information on marine applications,see DN-60688. <br /> -AMPS-24: 110-120 VAC,50/60 Hz,4.5 A maximum. STANDARDS <br /> -AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. The NFS2-3030 complies with the following UL Standards and <br /> DC Output: NFPA 72, International Building Code (IBC), and California <br /> -Main 24 VDC: Up to 5.0 A Building Code(CBC) Fire Alarm Systems requirements: <br /> • <br /> -Aux 24 VDC: Up to 5.0 A UL 864(Fire). <br /> -5 VDC: Up to 0.15 A. • <br /> UL 1076(Burglary). <br /> Current draw(Standby/Alarm): • UL 2572(Mass Notification Systems). <br /> -CPU2-3030D board:0.340 A. <br /> DN-7070:K•12/20/2013-Page 7 of 8 <br />