DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS AEM-48A: Same LED capabilities as ACM-48A; expands the
<br /> requires DS-XF70V step-up transformer. Digital Series Ampli- ACM-48A to 96 points.See DN-6862.
<br /> fier,part of the DS-DB system. See DN-60663. ACM-8R: Remote Relay Module with eight Form-C contacts.
<br /> DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for Can be located up to 6,000 ft. (1828.8 m) from panel on four
<br /> DVC-EM, DS-DB distribution board, and DAA2/DAX Series wires.See DN-3558.
<br /> amplifiers. See DN-60633. LCD-160: Liquid Crystal Display annunciator, 160-character
<br /> DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- backlit. Can store character sets for multiple languages. Sup-
<br /> bly with power supply;includes chassis. See DN-60556. ports Canadian requirements. See DN-6940.
<br /> DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier LCD2-80:Terminal and ACS mode. 80-character, backlit LCD
<br /> assembly with power supply;includes chassis.See DN-60556. display.Mounts up to 6,000 ft.(1828.8 m)from panel.Up to 32
<br /> DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly per FACP. See LCD2-80(DN-60548).
<br /> with power supply;includes chassis. See DN-60556. SCS Series: Smoke control station; eight(expandable to 16)
<br /> DAX-3525(E):35W,25 Vrms Digital Audio Amplifier assembly circuits. See DN-4818.
<br /> with power supply,includes chassis.See DN-60561. TM-4: Transmitter Module. Includes three reverse-polarity cir-
<br /> DAX-3570(E): 35W,70.7 Vrms Digital Audio Amplifier assem- cuits and one municipal box circuit. Mounts in panel module
<br /> bly with power supply,includes chassis.See DN 60561. position (as in single-address mode applications) or in CHS-
<br /> M3 position.See DN-6860.
<br /> DAX-5025(E):50W,25 Vrms Digital Audio Amplifier assembly UDACT 2: Universal Digital Alarm Communicator Transmitter,
<br /> with power supply, includes chassis. See DN-60561.
<br /> 636 channel.See DN-60686.
<br /> DAX-5070(E): 50W,70.7 Vrms Digital Audio Amplifier assem-
<br /> bly with power supply,includes chassis. See DN 60561. UZC-256: Programmable Universal Zone Coder provides pos-
<br /> itive non-interfering successive zone coding. Microprocessor-
<br /> TELH-1: Firefighter's Telephone Handset for use with the controlled, field-programmable from IBM®-compatible PCs
<br /> DVC-EM when mounted in the CA-2 chassis. See DN-7045. (requires optional programming kit). Mounts on a CHS-4
<br /> CMIC-1: Microphone used with DVC/DVC-EM. Included with series chassis within NFS2-3030.
<br /> CA-2 chassis assembly.See DN 7045. COMPATIBLE INTELLIGENT DEVICES
<br /> RM-1/RM-1SA: Remote microphone assemblies, mount on FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing
<br /> ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) Technology®. Intelligent aspirating smoke detector. For Cana-
<br /> stand-alone cabinets.See DN-6728. dian applications,order FSA-8000A.See DN-60792.
<br /> AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier FSB-200: Intelligent beam smoke detector. See DN-6985.
<br /> and audio input supervision, backup input,and automatic swi-
<br /> tchover,power supply,cables.See DN-3224. FSB-200S: Intelligent beam smoke detector with integral sen-
<br /> AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25
<br /> sitivity test.See DN-6985.
<br /> Vrms.AA-100 is 100 watts,70.7 Vrms.The amplifier contains FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria
<br /> an integral chassis for mounting to a CAB-B4, -C4, or -D4 Detector. See DN-60412.
<br /> backbox(consumes one row).Includes audio input and ampli- FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite-
<br /> fied output supervision, backup input, and automatic switcho- ria Fire/CO Detector.See DN-60689.
<br /> ver to backup tone.See DN 3224. FSI-851: Low-profile FlashScan ionization detector. See DN-
<br /> DAA Series Digital Audio Amplifiers: Legacy DAA Series 6985.
<br /> amplifiers are compatible with DVC systems running SR4.0. FSP-851: Low-profile FlashScan photoelectric detector. See
<br /> For specific information on DAA-50 series amplifiers, refer to
<br /> DN-7046. For information on DAA-7525 Series, refer to DN- DN-6935.
<br /> 60257. FSP-851R: Low-profile intelligent photoelectric sensor,remote
<br /> COMPATIBLE DEVICES,EIA-232 PORTS test capable.For use with DNR(W).See DN-6935.
<br /> PRN-6:80 column printer.See DN 6956. FSP-851 T: Low-profile FlashScan photoelectric detector with
<br /> 135°F(57°C)thermal.See DN-6935.
<br /> VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. FST-851: FlashScan thermal detector 135°F (57°C). See DN-
<br /> See DN-3260. 6936.
<br /> DPI-232: Direct Panel Interface, specialized modem for FST-851R: FlashScan thermal detector 135°F (57°C) with
<br /> extending serial data links to remotely located FACPs and/or rate-of-rise. See DN-6936.
<br /> peripherals. See DN-6870.
<br /> FST-851H: FlashScan 190°F(88°C)high-temperature thermal
<br /> COMPATIBLE DEVICES,EIA-485 PORTS detector. See DN-6936.
<br /> ACM-24AT:ONYX®Series ACS annunciator-up to 96 points FAPT 851: FlashScan Acclimate PIusTM low-profile multi-sen-
<br /> of annunciation with Alarm or Active LED, Trouble LED, and sor detector. See DN-6937.
<br /> switch per circuit. Active/Alarm LEDs can be programmed (by FSL-751: FlashScan VIEW® laser photo detector. See DN-
<br /> powered-up switch selection)by point to be red,green,or yel- 6886.
<br /> low;the Trouble LED is always yellow.See DN-6862.
<br /> AEM-24AT: Same LED and switch capabilities as ACM-24AT; DNR: InnovairFlex low flow non relay duct detector housing
<br /> expands the ACM-24AT to 48,72,or 96 points.See DN-6862. (order FSP-851 separately). Replaces FSD-751 PL/FSD-
<br /> 751 RPL. See DN-60429.
<br /> ACM-48A: ONYX®Series ACS annunciator-up to 96 points
<br /> of annunciation with Alarm or Active LED per circuit. Active/ DNRW: Same as above with NEMA-4 rating, watertight. See
<br /> Alarm LEDs can be programmed(by powered-up switch selec- DN-60429.
<br /> tion)in groups of 24 to be red,green,or yellow. Expandable to B224RB: Low-profile relay base.See DN-60054.
<br /> 96 points with one AEM-48A. See DN-6862.
<br /> DN-7070:K•12/20/2013-Page 5 of 8