My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> C. Pipe Alignment Guides: Factory fabricated, of cast semi-steel or heavy fabricated steel, consisting of bolted two- <br /> section outer cylinder and base with two-section guiding spider that bolts tightly to pipe. Length of guides shall be <br /> as recommended by manufacturer to allow indicated travel. <br /> ' PART 3: EXECUTION <br /> ' 3.01 EXAMINATION <br /> A. Examine substrates and conditions under which supports and anchors are to be installed. Do not proceed with <br /> installing until unsatisfactory conditions have been corrected. <br /> ' 3.02 INSTALLATION OF HANGERS AND SUPPORTS <br /> A. General: Install hangers, supports, clamps and attachments to support piping properly from building structure; <br /> comply with MSS SP-69 and SP-89. Arrange for grouping of parallel runs of horizontal piping supported together <br /> on field-fabricated,heavy-duty trapeze hangers where possible. Install supports with maximum spacings complying <br /> with MSS SP-69. Where piping of various sizes is supported together by trapeze hangers, space hangers for <br /> smallest pipe size or install intermediate supports for smaller diameter pipe as specified above for individual pipe <br /> hangers. <br /> ' B. Install building attachments within concrete or to structural steel. Space attachments within maximum piping span <br /> length indicated in MSS SP-69. Install additional attachments at concentrated loads, including valves, flanges, <br /> guides, strainers,expansion joints and at changes in direction of piping. Install concrete inserts before concrete is <br /> ' placed; fasten insert to forms. Where concrete with compressive strength less than 2,500 psi is indicated, install <br /> reinforcing bars through openings at top of inserts. <br /> C. Install hangers and supports complete with necessary inserts,bolts,rods,nuts,washers,and other accessories. <br /> D. Field-Fabricated,Heavy Duty Steel Trapezes: Fabricate from steel shapes selected for loads required;weld steel in <br /> accordance with AWS D-1.1. <br /> E. Support fire protection systems piping independently from other piping systems. <br /> ' F. Install hangers and supports to allow controlled movement of piping systems, to permit freedom of movement <br /> between pipe anchors, and to facilitate action of expansion joints, expansion loops, expansion bends and similar <br /> units. <br /> ' G. Load Distribution: Install hangers and supports so that piping live and dead loading and stresses from movement <br /> will not be transmitted to connected equipment. <br /> H. Pipe Slopes: Install hangers and supports to provide indicated pipe slopes, and so that maximum pipe deflections <br /> allowed by ASMI B31.9 Building Services Piping Code is not exceeded. <br /> I. Insulated Piping: Comply with the following installation requirements. <br /> ' 1. Clamps: Attach clamps,including spacers(if any),to piping with clamps projecting through insulation;do not <br /> exceed pipe stresses allowed by ASME B31.9. <br /> e2. Saddles: Install protection saddles MSS Type 39 where insulation without vapor barrier is indicated. Fill <br /> interior voids with segments of insulation that match adjoining pipe insulation. <br /> ' 3. Shields: Install protective shields MSS Type 40 on cold and hydronic water piping that has vapor barrier. <br /> Shields shall span an arc of 180 degrees and shall have dimensions in inches not less than the following: <br /> 15140-3 No. [COMM] <br />