My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. Maintenance data for supports and anchors for inclusion in Operating and Maintenance Manual specified in ' <br /> Division 1 and Division 15 Section 15010"Basic Mechanical Requirements". <br /> 1.05 QUALITY ASSURANCE ' <br /> A. Qualify welding processes and welding operators in accordance with AWS Dl.I "Structural Welding Code-Steel". <br /> B. Qualify welding processes and welding operators in accordance with ASME 'Boiler and Pressure Vessel Code," ' <br /> Section IX,"Welding and Brazing Qualifications". <br /> C. Regulatory Requirements: Comply with applicable codes pertaining to product materials and installation of ' <br /> supports and anchors. <br /> D. NFPA Compliance: Hangers and supports shall comply with NFPA standard No. 13 when used as a component of a <br /> fire protection piping systems. ' <br /> E. UL and FM Compliance: Hangers,supports,and components shall be listed and labeled by UL and FM where used <br /> for fire protection piping systems. <br /> F. Nationally Recognized Testing Laboratory and NEMA Compliance (NRTL): Hangers, supports, and components <br /> shall be listed and labeled by a NRTL where used for fire protection piping systems. The term"NRTL"shall be as <br /> defined in OSHA Regulation 1910.7. ' <br /> PART 2: PRODUCTS ' <br /> 2.01 MANUFACTURED UNITS <br /> A. Hangers and support components shall be factory fabricated of materials,design,and manufacturer complying with ' <br /> MSS SP-58. <br /> 1. Components shall have galvanized coatings where installed for piping and equipment that will not have field- ' <br /> applied finish. <br /> 2. Pipe attachments shall have nonmetallic coating for electrolytic protection where attachments are in direct ' <br /> contact with copper tubing. <br /> 3. Use of C-clamp type beam clamps,MSS Types 19 and 23,for attaching to structural members,are to be used <br /> only when installed with restraining straps designed by the hanger manufacturer for the purpose of restraining , <br /> c-clamp hangers. <br /> B. Thermal Hanger Shield Inserts: 100-psi average compressive strength,waterproofed calcium silicate,encased with ' <br /> a sheet metal shield. Insert and shield shall cover entire circumference of the pipe and shall be of length indicated <br /> by manufacturer for pipe size and thickness of insulation. <br /> 2.02 MISCELLANEOUS MATERIALS <br /> A. Steel Plates,Shapes,and Bars: ASTM A 36. <br /> B. Cement Grout: Portland cement (ASTM C 150, Type I or Type lIn and clean uniformly graded, natural sand 1 <br /> (ASTM C 404,Size No.2). Mix ratio shall be 1.0 part cement to 3.0 parts sand,by volume,with minimum amount <br /> of water required for placement and hydration. <br /> 15140-2 No.[COMM] <br />
The URL can be used to link to this page
Your browser does not support the video tag.