My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E. High Strength Bolted Construction Assembly: Tighten in accordance with Section 5, reference "Specification for <br /> Structural Joints Using ASTM A325 or A490 bolts." <br /> ' F. Welded Construction: In accordance with"AWS"reference specification. <br /> G. Gas Cutting: Field correcting of fabrication by gas cutting is not permitted on members in the structural framing <br /> without prior approval of the Architect. <br /> H. Paint Touch-up: After erection of structural steel,touch-up paint field connections,bolt heads and nuts,welds and <br /> abrasions in the shop paint coating,with same paint used for shop painting. <br /> ' I. Repair galvanizing after completion of field welding according to ASTM A780. <br /> J. Install expansion bolts and adhesive anchors in strict accordance with manufacturer's instructions. <br /> 3.02 FIELD QUALITY CONTROL <br /> ' A. Special Structural Testing and Inspection <br /> 1. Special Structural Testing and Inspection and Conventional Testing and Inspection shall be performed by <br /> qualified parties as specified herein and in accordance with the provisions of Section 01410. <br /> ' 2. If special inspection of Fabricator's work is required, special inspector may test and inspect structural steel at <br /> plant before shipment. <br /> ' 3. Qualifying Agencies: <br /> a. A.S.N.T.: The American Society for Non-destructive Testing <br /> b. N.D.E: Non-destructive Evaluation <br /> ' C. A.W.S./C.A.W.I.: American Welding Society/Certified Associate Weld Inspector <br /> d. A.W.S./C.W.I.: American Welding Society/Certified Weld Inspector <br /> 4. Personnel Qualifications: <br /> a. Special Inspector - Technical: Shall be employed by a testing agency and shall be supervised by an <br /> ' A.W.S./C.W.I.with a minimum of 10 years experience or an A.S.N.T. Level III with a minimum of 10 <br /> years experience. Individuals shall satisfy the following requirements: <br /> 1.) Technical I: Non-destructive Testing Technician A.S.N.T.-TC-IA Level 1,and/or A.W.S./C.A.W.I. <br /> 2:), Technical II: Non-destructive Testing Technician A.S.N.T.-TC-IA Level II, (NDE Technician II), <br /> A.W.SJC.A.W.I.,with minimum 3 years experience,or an A.W.SJC.W.I. <br /> 3.) Technical III: A.S.N.T.Level III with a minimum of 10 years experience or an A.W.SJC.W.I.with <br /> a minimum of 10 years experience. <br /> 5. The Owner will provide the following tests and inspections: <br /> a. Test high strength bolted connections according to the requirements of R.C.S.C. "Specification for <br /> Structural Joints Using ASTM A325 or ASTM A490 Bolts",UBC Standard 27-7 and as follows: <br /> 1.) Preparation: Visually inspect mating surfaces and bolt type for all bolted connections for general <br /> ' conformance with the contract documents prior to bolting. Qualifications: Technical H. <br /> 05100-5 No.99132-CP2 <br />