My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 2.) Slip Critical Bolts and Tension Bolts: Test bolt tightening in 10%of all bolts. Test a minimum of ' <br /> two bolts in each connection. Verify that all plies connected elements have been brought into <br /> contact at 100%of connections. Verify all tips are removed from"twist-off'bolts. Qualifications: ' <br /> Technical H. <br /> 3.) Bearing Bolts: Visually inspect to confirm all plies of connected elements have been brought into <br /> contact at 100% of connections. (Applies only to bolts designed with threads included in failure ' <br /> plane;all other bolts require testing as for tension bolts.) Qualifications: Technical II. <br /> 4.) Shop Fabricated Work: Delete bolt testing if fabrication shop satisfies AISC Quality Certification ' <br /> Program - Category I, or more stringent criteria, or is approved by Building Official and SER <br /> Special Inspector to determine if the above requirements are met. <br /> b. Test welding as follows: ' <br /> 1.) Fillet Welds: Visually inspect 100%of all fillet welds,for size,length,and quality,per AWS D1.1. <br /> Qualifications: Technical H. ' <br /> 2.) Partial Penetration Welds: Test 100% of all partial penetration welds exceeding 5/16 inch, using <br /> Ultrasonic Testing per AWS D1.1, Section 6. Test 25% of all penetration welds less than 5/16 <br /> inch, using Magnetic Particle Testing per ASTM E-109 performed on root pass and on finished ' <br /> weld. Qualifications: Technical 11. <br /> 3.) Full Penetration Welds: Test 100% of all full penetration welds exceeding 5/16 inch, using ' <br /> Ultrasonic Testing per AWS D1.1 Section 6. Test 25%of all full penetration welds less that 5/16 <br /> inch, using Magnetic Particle Testing per ASTM E-109 performed on root pass and on finished <br /> weld. Qualifications: Technical II. <br /> 4.) Procedures and Preparation: Verify the following: <br /> a). Qualifications of all welders as AWS certified. ' <br /> b.) Proposed welding procedures and materials. <br /> c.) Adequate preparation of faying surfaces. <br /> d.) Preheat and interpass temperatures of steel, proper technique and sequence of welding, and ' <br /> cleaning and number of passes. <br /> Qualifications: Technical 1I <br /> 5.) Shop Fabricated Work: Delete fillet weld and partial penetration weld testing if fabrication shop , <br /> satisfies AISC Quality Certification Program-Category I,or more stringent criteria,or is approved <br /> by Building Official and SER Special Inspector to determine if the above requirements are met. <br /> C. Expansion Bolting and Adhesive Anchoring: Be present on the job site continuously during installation ' <br /> to verify bolt type and dimensions, concrete type and compressive strength,pre-drilled hole dimensions, <br /> embedment,spacing,edge distances,slab thickness,and tightening torque. ' <br /> Qualifications: Technical H. <br /> END OF SECTION 05100 <br /> 05100-6 No.99132-CP2 ' <br />