My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Keep steel forms heated by sun and wood forms in contact with concrete during final curing period wet. If forms <br /> are to be removed during curing period,employ one of specified curing materials or methods immediately. <br /> E. When mean daily temperature of atmosphere is less than 50°F,maintain the temperature of concrete between 50°F <br /> and 60°F for curing period. Make the arrangements for heating, covering, insulating or housing concrete work in <br /> advance of placement and maintain required temperature and moisture conditions without injury due to <br /> concentration of heat. Vent all fuel-burning heaters. <br /> F. During hot weather,make arrangements for installation of windbreaks,shading,fog spraying,sprinkling,ponding or <br /> wet covering in advance of placement and take such protective measures as quickly as concrete hardening and <br /> finishing operations will allow. <br /> G. Changes in temperature of concrete shall be as uniform as possible and shall not exceed 5°F in any 1 hour or 50°F <br /> in any 24 hour period. <br /> 3.07 FIELD QUALITY CONTROL <br /> A. Special Structural Testing and Inspection <br /> 1. Special Structural Testing and Inspection shall be performed by qualified parties as specified herein, and in <br /> accordance with the provision of Section 01410. <br /> 2. Personnel Qualifications: ' <br /> a. Special Inspector-Technical: <br /> 1.) Technical I - ACI Certified Grade I Technician. Inspector shall be employed by a testing <br /> laboratory,under the direct supervision of a registered civil/structural engineer. <br /> 2.) Technical II - ACI Certified Grade II Inspector. Inspector shall be employed by a testing <br /> laboratory,under the direct supervision of a registered civil/structural engineer. <br /> 3.) Technical III-A civil/structural engineer regularly engaged in this type of work,with a initnnm of <br /> 4 years experience and registered in the State in which the project is located and is an employee of a <br /> qualified and approved testing laboratory. The registered engineer shall review and approve all <br /> reports. <br /> b. Special Inspector-Structural: <br /> 1.) Structural I - Graduate civi/structinal engineer, or other personnel acceptable to the Structural <br /> Engineer of Record (SER), with the experience in the design of structural systems of this type. <br /> Inspection shall be performed under the direct supervision of a registered civil/structural engineer. <br /> 2.} Structural II-Civil/structural engineer regularly engaged in the design of structural systems of this <br /> type,registered in the state in which the project is located. The registered engineer shall review and <br /> approve all inspection reports. <br /> 3. The Owner will employ a Special Inspector for the following inspections: <br /> a. Tests for cast in place concrete. Qualifications: Technical I. <br /> 1.) Prepare compression test specimens(ASTM C31),one set of four standard cylinders of concrete for <br /> each compressive strength test. Mold and store cylinders for laboratory cured specimens. <br /> 03300-10 No.99132-CP2 <br />