My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01358 - new structutre
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
4680 North Shore Drive - 07-117-23-32-0050
>
Permits/Inspections
>
2014-01358 - new structutre
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:35:40 PM
Creation date
1/30/2018 12:38:08 PM
Metadata
Fields
Template:
x Address Old
House Number
4680
Street Name
North Shore
Street Type
Drive
Address
4680 North Shore Dr
Document Type
Permits/Inspections
PIN
0711723320050
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.EE <br /> Auer Steel(New Hope) Midwest Custom Const.I <br /> Plymouth,MN 55441 Page 8 j <br /> Detailed Room Loads - Room 1 - Main Floor (Average Load Procedure) <br /> General <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 38.0 ft. System Number: 1 <br /> Room Width: 28.0 ft. Zone Number: 1 <br /> Area: 1,064.0 sq.ft. Supply Air: 572 CFM <br /> Ceiling Height: 9.0 ft. Supply Air Changes: 3.6 AC/hr <br /> Volume: 9,576.0 cu.ft. Req.Vent. Clg: 0 CFM <br /> Number of Registers: 5 Actual Winter Vent.: 72 CFM <br /> Runout Air: 114 CFM Percent of Supply.: 13 % <br /> Runout Duct Size: 6 in. Actual Summer Vent.: 73 CFM <br /> Runout Air Velocity: 583 ft./min. Percent of Supply: 13 % <br /> Runout Air Velocity: 583 ft./min. Actual Winter Infil.: 51 CFM <br /> Actual Loss: 0.212 in.wg./100 ft. Actual Summer Infil.: 25 CFM <br /> item - Area --U- - Htg - Sen Clg Lat Sen <br /> _0escri tion Quantity Value HTM Loss HTM Gain Gain <br /> N-Wall-12E-Osw 34 X 9 291 0.068 6.3 1,820 1.7 0 503 <br /> E-Wall-1 2E-Osw 26 X 9 183 0.068 6.3 1,145 1.7 0 316 <br /> E-Part-100/700-12E-Osw 17.5 X 9 157.5 0.068 4.8 750 0.7 0 107 <br /> S-Wall-12E-Osw 18 X 9 162 0.068 6.3 1,013 1.7 0 280 <br /> S-Part-100/70°-12E-Osw 16 X 9 144 0.068 4.8 685 0.7 0 98 <br /> W-Wall-12E-Osw 46 X 9 325 0.068 6.3 2,033 1.7 0 561 <br /> W-Door-11 P 3 X 7 21 0.290 26.7 560 9.9 0 207 <br /> N-GIs-2A-v-o shgc-0.61 100%S 15 0.550 50.6 759 24.2 0 363 <br /> E-GIs-2A-v-o shgc-0.61 0%S 40.5 0.550 50.6 2,049 69.7 0 2,822 <br /> E-GIs-2A-v-o shgc-0.61 0%S 10.5 0.550 50.6 531 69.7 0 732 <br /> W-GIs-2A-v-o shgc-0.61 0%S (2) 36 0.550 50.6 1,822 69.7 0 2,508 <br /> W -GIs-2A-v-o shgc-0.61 0%S (2) 14 0.550 50.6 708 69.7 0 976 <br /> W-GIs-2A-v-o shgc-0.61 0%S 18 0.550 50.6 911 69.7 0 1,254 <br /> UP-Ceil-16B-30 18 X 6 108 0.032 2.9 318 1.9 0 200 <br /> Floor-l9B-s8.25p 28 X 38 1064 0.036 1.7 1,756 0.4 0 439 <br /> Subtotals for Structure: 16,860 0 11,366 <br /> Infil.:Win.:51.0, Sum.:25.5 1,116 4.487 5,007 0.561 510 626 <br /> AED Excursion: 216 <br /> Room Totals: 21,867 510 12,208 <br /> C:\...Wlidwest Custom Const- Countryside Solutions.rhv Thursday, November 20, 2014, 9:36 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.