My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-01358 - new structutre
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
4680 North Shore Drive - 07-117-23-32-0050
>
Permits/Inspections
>
2014-01358 - new structutre
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:35:40 PM
Creation date
1/30/2018 12:38:08 PM
Metadata
Fields
Template:
x Address Old
House Number
4680
Street Name
North Shore
Street Type
Drive
Address
4680 North Shore Dr
Document Type
Permits/Inspections
PIN
0711723320050
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Auer Steel(New Hope) Midwest Custom Const. <br /> Plymouth,MN 55441 In Page 9 <br /> Detailed Room Loads - Room 2 - Second Floor (Average Load Procedure) <br /> General <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 44.0 ft. System Number: 1 <br /> Room Width: 28.0 ft. Zone Number: 1 <br /> Area: 1,232.0 sq.ft. Supply Air: 520 CFM <br /> Ceiling Height: 8.0 ft. Supply Air Changes: 3.2 AC/hr <br /> Volume: 9,856.0 cu.ft. Req. Vent. Clg: 0 CFM <br /> Number of Registers: 5 Actual Winter Vent.: 68 CFM <br /> Runout Air: 104 CFM Percent of Supply.: 13 % <br /> Runout Duct Size: 6 in. Actual Summer Vent.: 67 CFM <br /> Runout Air Velocity: 529 ft./min. Percent of Supply: 13 % <br /> Runout Air Velocity: 529 ft./min. Actual Winter Infil.: 53 CFM <br /> Actual Loss: 0.175 in.wg./100 ft. Actual Summer Infil.: 26 CFM <br /> Item Area -U- Htg Sen Clg Lat Sen <br /> Description Quantity Value HTM Loss HTM Gain Gain <br /> N -Wall-12E-Osw 28 X 8 208 0.068 6.3 1,301 1.7 0 359 <br /> E -Wall-12E-Osw 44 X 8 337 0.068 6.3 2,108 1.7 0 582 <br /> S -Wall-12E-Osw 28 X 8 194 0.068 6.3 1,214 1.7 0 335 <br /> W -Wall-1 2E-Osw 44 X 8 307.2 0.068 6.3 1,922 1.7 0 531 <br /> N -GIs-2A-v-o shgc-0.61 100%S 16 0.550 50.6 810 24.2 0 387 <br /> E -GIs-2A-v-o shgc-0.61 0%S 15 0.550 50.6 759 69.7 0 1,045 <br /> S -GIs-2A-v-o shgc-0.61 0%S (2) 30 0.550 50.6 1,518 40.4 0 1,212 <br /> W -GIs-2A-v-o shgc-0.61 0%S 8.8 0.550 50.6 443 69.7 0 610 <br /> W -GIs-2A-v-o shgc-0.61 0%S (2) 36 0.550 50.6 1,822 69.7 0 2,508 <br /> UP-Ceil-16A-38 44 X 28 1232 0.026 2.4 2,947 2.0 0 2,498 <br /> Floor-20P-30 18 X 16 288 0.035 3.2 927 0.6 0 181 <br /> Subtotals for Structure: 15,771 0 10,248 <br /> Infil.: Win.: 52.6, Sum.: 26.3 1,152 4.487 5,169 0.561 526 646 <br /> AED Excursion: 196 <br /> Room Totals. 20,940 526 11,090 <br /> C:\...\Midwest Custom Const - Countryside Solutions.rhv Thursday, November 20, 2014, 9:36 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.