Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> Sabre Plumbing&Heating • 765 Lakeview Parkway Orono
<br /> Plymouth,MN 55447 Page 3
<br /> Load Preview Report
<br /> Net ft. Sen Lat Net Sen HtSys Cl Sys
<br /> Act Duct
<br /> Scope Ton /Ton Area Gain Gain Gain Loss g g Size
<br /> CFM CFM CFM'.
<br /> Building 3.71 1,289 4,776 38,925 5,540 44,464 69,582 833 1,772 1,772
<br /> System 1 3.71 1,289 4,776 38,925 5,540 44,464 69,582 833 1,772 1,772 18x18
<br /> Ventilation 1,054 4,409 5,463 7,057
<br /> Supply Duct Latent 91 91
<br /> Return Duct 45 40 85 300
<br /> Humidification 7,052
<br /> Zone 1 4,776 37,826 1,000 38,826 55,173 833 1,772 1,772 18x18
<br /> 1-Lower Level 1,418 7,651 0 7,651 15,334 231 358 358 4--6
<br /> 2-Sport Court 450 1,920 0 1,920 8,750 132 90 90 1--6
<br /> 3-Main Level 1,418 18,985 1,000 19,985 17,541 265 889 889 9--6
<br /> 4-Upper Level 1,490 9,270 0 9,270 13,548 205 434 434 4--6
<br /> M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM
<br />
|