My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01610 - new structure
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
765 Lakeview Parkway - 06-117-23-34-0010
>
Permits/Inspections
>
2017-01610 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:32 PM
Creation date
1/24/2018 12:23:35 PM
Metadata
Fields
Template:
x Address Old
House Number
765
Street Name
Lakeview
Street Type
Parkway
Address
765 Lakeview Pkwy
Document Type
Permits/Inspections
PIN
0611723340010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing&Heating 1765 Lakeview Parkway Orono <br /> Plymouth,MN 55447 Page 2 I <br /> Project Report <br /> General Project Information <br /> Project Title: 765 Lakeview Parkway Orono <br /> Designed By: Josh Gray <br /> Project Date: Wednesday, October 11, 2017 <br /> Client Name: Gonyea Homes <br /> Company Name: Sabre Heating And A/C <br /> Company Representative: Josh Gray <br /> Company Address: 15535 Medina Road <br /> Company City: Plymouth, Mn 55447 <br /> Company Phone: 763-473-2267 <br /> Company Fax: 763-473-8565 <br /> Company E-Mail Address: josh.gray@sabreheating.com <br /> Design Data <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -15 -12.38 n/a 30% 72 29.40 <br /> Summer: 88 73 50% 50% 75 35 <br /> Check Figures <br /> Total Building Supply CFM: 1,772 CFM Per Square ft.: 0.371 <br /> Square ft. of Room Area: 4,776 Square ft. Per Ton: 1,289 <br /> Volume (ft') of Cond. Space: 46,444 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 69,582 Btuh 69.582 MBH <br /> Total Sensible Gain: 38,925 Btuh 88 % <br /> Total Latent Gain: 5,540 Btuh 12 % <br /> Total Cooling Required Including Ventilation Air: 44,464 Btuh 3.71 Tons (Based On Sensible + Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.