Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing&Heating I. 765 Lakeview Parkway Orono <br /> Plymouth,MN 55447 Page 4 <br /> Total Building Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> LOW EE: Glazing-Builder Grade Low E Windows& 523.5 14,573 0 16,330 16,330 <br /> Sliding Door.32 U value .30 SHGC, u-value 0.32, <br /> SHGC 0.3 <br /> 11J: Door-Metal - Fiberglass Core 40 2,088 0 576 576 <br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 1467 5,823 0 130 130 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 15A-10sffc-4: Wall-Basement, concrete block wall, R-10 20 87 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 4'floor depth <br /> R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 3525.5 20,242 0 3,094 3,094 <br /> siding finish, wood studs <br /> RJ R20 Closed Cell: Wall-Frame, Custom, Spray Foam R- 510 2,220 0 392 392 <br /> 20 <br /> R49- 16B-49: Roof/Ceiling-Under Attic with Insulation on 1940 3,881 0 2,142 2,142 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R49 Blown Insulation-vented <br /> attic, asphalt shingles <br /> 21A-20-c: Floor-Basement, Concrete slab, any thickness, 1868 4,388 0 0 0 <br /> 2 or more feet below grade, no insulation below floor, <br /> carpet covering, shortest side of floor slab is 20'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 182 554 0 51 51 <br /> R-30 blanket insulation, any cover <br /> Subtotals for structure: 53,856 0 22,715 22,715 <br /> People: 5 1,000 1,150 2,150 <br /> Equipment: 0 4,116 4,116 <br /> Lighting: 1250 4,263 4,263 <br /> Ductwork: 1,617 131 331 462 <br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 190, Summer CFM: 190 7,057 4,409 1,054 5,463 <br /> Humidification (Winter) 19.23 gal/day : 7,052 0 0 0 <br /> AED Excursion: 0 0 5,296 5,296 <br /> Total Building Load Totals: 69,582 5,540 38,925 44,464 <br /> Check Figures <br /> Total Building Supply CFM: 1,772 CFM Per Square ft.: 0.371 <br /> Square ft. of Room Area: 4,776 Square ft. Per Ton: 1,289 <br /> Volume (ft')of Cond. Space: 46,444 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 69,582 Btuh 69.582 MBH <br /> Total Sensible Gain: 38,925 Btuh 88 % <br /> Total Latent Gain: 5,540 Btuh 12 % <br /> Total Cooling Required Including Ventilation Air: 44,464 Btuh 3.71 Tons(Based On Sensible + Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:\Sales and Estimating\Heat Calcs\Gonyea\765 Lakeview Parkway Orono.rh9 Wednesday, October 11, 2017, 8:15 AM <br />