Page 4 of 8 <br /> NIMICING® <br /> QUICK RESPONSE <br /> TECHNICAL DATA DRY HORIZONTAL <br /> SIDEWALL SPRINKLERS <br /> • <br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 <br /> Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com <br /> • <br /> • <br /> Sprinkler Base Thread Size Nominal Order Length Listings and Approvals4 <br /> Part No) SIN Style K-Factor° increment (Refer also to DesignCriteria on page 106e.) <br /> NPT BSP ® metric' Inches ® cULus5 NYC° VdS LPCB Egg la <br /> 08384U VK178 Adjustable 1° — 5.6 80.6 1/2" ® Al,A5 Al 0 -- 11.111111 <br /> 16458U Standard — 25 mm ME 80.6 1/2" ® Al A5 — — as <br /> 08386U VK182 Adjustable 1" -- 80,6 1/4' 6.35 B2, B6 B2 1111 -- ©MI <br /> 16454U Recessed -- 25 mm 80.6 1/4" 6.35 B2,B6 -- a -- 111.111.111 <br /> 0838816456U VK174 Plain Barrel 1" — 5.6 80.6 112" 12.7 A3 A4 _ �� <br /> 16456U -- 25 mm 0 80.6 1/2" ® A3 <br /> Approved Finishes and"A"Dimensions <br /> 1* -Chrome, or White Polyester'sprinkler with a Chrome, Brass, or White Polyester Sleeve and <br /> Escutcheon with"A"dimensions 1-1/2"to 45-1/2'(38.1 mm to 1,156 mm) <br /> Approved Temperature Ratings 2 -Chrome, or White Polyester'with "A"dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 <br /> A-155°F(68°C), 175"F(79"C),200°F 3-Chrome,Brass,White Polyester',or ENT'with'A"dimensions 3"to 47"(76.2 mm to 1,194 mm) <br /> (93°C),and 286°F(141 °C) 4-Chrome or Brass with"A'dimensions 3"to 47"(76.2 mm to 1,194 mm) <br /> B-155 °F (68 °C), 175°F (79°C), and 5-ENT' <br /> 200°F(93°C) sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 <br /> mm to 1,156 mm) <br /> 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) <br /> 'Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. <br /> (Matching Brass escutcheons are not available.) <br /> Footnotes <br /> 'Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. <br /> 2 K-Factor applies for standard lengths("A"Dimensions indicated above). <br /> Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. <br /> 'This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer <br /> for any additional approvals. <br /> 5 Listed by Underwriter's Laboratories for use in the U.S-and Canada for Light Hazard occupancies only. <br /> 6 Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.15. <br /> 'cULus Listed as corrosion resistant. <br /> NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nlbco Model 5012-S-BI tees.When selecting other CPVC fittings, <br /> contact Viking Technical Services. <br /> cULus Listing Reauirements: <br /> Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- <br /> tion of NFPA 13 for standard spray sprinklers. <br /> • Limited to Light Hazard occupancies only. <br /> • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br /> • Minimum spacing allowed is 6 ft.(1.8 m). <br /> • Deflector must be positioned between 4"and 6"(102 mm and 152 mm)below the ceiling.Keep the top of the deflector oriented parallel with <br /> the ceiling. <br /> • Locate no less than 4"(102 mm)from end walls. <br /> • Maximum distance from end walls shalt be no more than one-half of the allowable distance between sprinklers.The distance shall be measured <br /> perpendicular to the wall. <br /> •The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. <br /> IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for <br /> general care, installation, and maintenance information. Viking sprinklers are to be installed In accordance with the latest <br /> edition of Viking technical data,the appropriate standards of NFPA, LPCB,APSAD,VdS or other similar organizations,and <br /> also with the provisions of governmental codes,ordinances,and standards,whenever applicable. <br /> Form No. F_031993 Rev 15.1 <br />