My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Renovate/addition project manual-1997
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2625 North Shore Drive - 09-117-23-42-0003
>
Misc
>
Renovate/addition project manual-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:23 PM
Creation date
10/19/2017 12:55:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2625
Street Name
North Shore
Street Type
Drive
Address
2625 North Shore Dr
Document Type
Misc
PIN
0911723420003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
for setting in the poured concrete trench. Provide a no traffic area drain in � <br /> the bottom of the poured concrete trench as shown and schedules on the <br /> Drawings. � <br /> G. Grout and caulk all fixtures with water and mildew resistant white epoxy silicone equal <br /> to Hydroment or pow Corning No. 786. Grout shall not exceed 1/4" width and shall � <br /> be installed flush with finished wall or floor. <br /> H. All fixture installation dimensions shall be determined from the Architectural � <br /> documents. <br /> I. Rough-in, install and make final connections forall plumbing fixtures furnished under <br /> another division of the specifications. � <br /> J. Contractor shall coordinate all floor joist headering required for piping installation. <br /> Headering shall be done at contractors expense. � <br /> K. Sump Basin (SB): Basin and cover shall be fiberglass (SB-24" wide x 30" deep). <br /> Install flush with finished floor and provide cover capable of supporting car tr�c. <br /> Verify depth required. Cover to be vented. � <br /> L. Sump Pumps (SP): Zoeller (Enpo, Hydromatic, Weil) as scheduled. Pump shall be <br /> submersible with permanently lubricated bearings, stainless steel shaft, cast iron � <br /> housing and galvanized strainer. <br /> 1. Simplex: provide with variable level piggyback level float switch and alarm. <br /> 2. All control and alarm wiring shall be by the mechanical contractor. Provide non- � <br /> slam check valve and shut off valve for pump. Pipe discharge as shown on <br /> drawing. <br /> M. Condensate Drains: , <br /> 1. Provide a deep seal "P" trap at condensate drain beneath each air conditioning unit <br /> cooling coil, and extend piping to nearest floor drain, service sink or as shown on <br /> drawings. � <br /> 2. Effective water seal of "P" trap shall be minimum of two times negative static <br /> pressure in fan plenum for draw-through fan unit, but not less than 3 inch. Depth <br /> of trap shall be minimum of one-half the plenum m�imum negative static � <br /> pressure. <br /> END OF SECTION � <br /> , <br /> � <br /> � <br /> � <br /> 070197 CBA701 8/1/97 � <br /> 15400 - 2 <br /> ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.