Laserfiche WebLink
, � � , � _ <br /> � ExH�c3�r F" <br /> . - .. � . . , ;, , ; . <br /> - - . - . -;: . . . - <br /> � .:.. . :. ;.- <br /> • 3403.2-3405 1994 UNIFORM BUILDING CODE <br /> . - -. •, . ._ <br /> . . . , . � _ -- <br /> _. .. • '�. <br /> � 1. The capaciry of existing structural elements required to resist forces is not reduced,and <br /> 2. The lateral loading to required existing swctural elements is not incceased beyond their capaciry,and <br /> 3. New structural elements are detailed and connected to the ezisting structural elements as required by. <br /> these rogulations,and � . <br /> 4. New or rolocated nonstructural elements are detailed and connected to ezisting or new suuctural ele- <br /> ments as required by these regulations,and <br /> 5. An unsafe condidon as defined above is not created. <br /> 34033 Nonstructural. Alterations or repairs to an existing building or structure which are non- <br /> structural and do not adversely affect any structural member or any part of the building or structure <br /> having required fire resistance may be made with the same materials of which the building or struc- <br /> mre is constructed. <br /> 3403.4 Glass Replacemen� The installation or replacement of glass shall be as required for new <br /> , installarions. . <br /> - 3403.5 Historic Buildings. Repairs,aiterations and additions necessary for the preservation,res- <br /> � - toration,rehabilitation or continued use of a building or structure may be made without confor- <br /> �� mance to all the requirements of this code when authorized by the building official,provided: <br /> � �� 1. The building or structure has been designated by official action of the legally constituted au- <br /> thority of this jurisdiction as having special historical or architectural significance. <br /> 2. Any unsafe conditions as described in this code are corrected. <br /> 3. The restored building or structure will be no more hazardous based on life safety,firesafety <br /> and sanitation than the existing building. <br /> SECTION 3404—MOVED BUILDINGS <br /> Buildings or structures moved into or within the jurisdiction shall comply with the pmvisions of this <br /> code for new buildings or structures. <br /> Se�. No-� o„ �^�"'°"> �pA'��- <br /> SECTION 3405—CHANGE IN USE <br /> No change shall be made in the character of occupancies or use of any building which would place <br /> the building in a different division of the same group of occupancy or in a different group of occu- <br /> pancies,unless such building is made to comply with the requirements of this code for such division <br /> or group of occupancy. � <br /> � EXCEPTION: The character of the occupancy of existing buildings may be changed subject W the ap- <br /> proval of the building official,and the building may be occupied forpurposes in othergroups without conform- <br /> _ ing to all the requirements of this code for those groups,provided the new or proposed use is less hazardous, <br /> based on life and fire risk,than the existing use. � <br /> No change in the character of occupancy of a building shall be made without a certificate of occu- <br /> pancy,as required in Section 109 of this code.The building official may issue a certificate of occu- <br /> ' pancy pursuant to the intent of the above exception without certifying that the building complies , <br /> . with all provisions of this code. <br /> 1�86 <br />