Laserfiche WebLink
--- <br /> Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabr? Plumbirig&Heating � 125 Kintyre Ln Orono <br /> PI mouth MN 55447 ___- --- --_ ___- ----- -- -- --- - -- Pa e 5 <br /> - _--- ---- __ _ _ -- -- __- ---- - <br /> S stem 2 Summ� Loads <br /> --- - __ - -_ _ __ _ <br /> --- <br /> __ _--- - _----- -- ----- -- <br /> Component Area Sen Lat Sen Total <br /> Description _ __ Quan Loss _ Gain_ _______Gain _ __ Gain <br /> LOW EE: Glazing-Builder Grade Low E Windows & 255.2 6,727 0 7,023 7,023 <br /> Sliding Door .33 U value .33 SHGC, u-value 0.31, <br /> SHGC 0.29 <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 3304.8 19,101 0 3,909 3,909 <br /> cavity, no board insulation, siding finish, wood studs <br /> RJ 10 Spray Foam: Wall-Frame, Custom, Closed Cell 228 1,938 0 550 550 <br /> R10 Spray Foam <br /> 166-44: Roof/Ceiling-Under Attic with Insulation on Attic 3154.7 5,899 0 3,471 3,471 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-44 insulation <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 53 158 0 19 19 <br /> R-30 blanket insulation, any cover <br /> 20P-38: Floor-Over open crawl space or garage, Passive, 1055.5 2,691 0 316 316 <br /> R-38 blanket insulation, any cover <br /> 21A-28: Floor-Basement, Concrete slab, any thickness, 2 715 1,337 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover,_shortest side of floor slab is 28'wide _ _ __ __ __ _ _ <br /> Subtotals for structure: 37,851 0 15,288 15,288 <br /> People: 0 0 0 0 <br /> Equipment: 0 478 478 <br /> Lighting: 0 0 0 <br /> Ductwork: 289 33 54 87 <br /> Infiltration: Winter CFM: 123, Summer CFM: 54 11,125 1,133 862 1,995 <br /> Ventilation: Winter CFM: 140, Summer CFM: 140 5,080 2,948 896 3,845 <br /> Exhaust: Winter CFM: 100, Summer CFM: 100 <br /> Humidification (Winter) 13,07_gal/day : . 4,794 _ 0 0 0 <br /> System 2 Load Totals: 59,139 4,114 17,579 21,693 <br /> Check Fiqures <br /> Supply CFM: 782 CFM Per Square ft.: 0.248 <br /> Square ft. of Room Area: 3,155 Square ft. Per Ton: 1,745 <br /> Volume (ft') of Cond. Space: 30,958 <br /> S stem Loads <br /> Total Heating Required Including Ventilation Air: 59,139 Btuh 59.139 MBH <br /> Total Sensible Gain: 17,579 Btuh 81 % <br /> Total Latent Gain: 4,114 Btuh 19 % <br /> Total Cooling Required Including Ventilation Air: 21,693 Btuh 1.81 Tons (Based On Sensible + Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary.� <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Gonyea 125 Kintrye Ln Orono WILSON.rh9 Friday, June 20, 2014, 4:08 PM <br />