<br /> Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> Sabr? Plumbirig&Heating � 125 Kintyre Ln Orono
<br /> PI mouth MN 55447 ___- --- --_ ___- ----- -- -- --- - -- Pa e 5
<br /> - _--- ---- __ _ _ -- -- __- ---- -
<br /> S stem 2 Summ� Loads
<br /> --- - __ - -_ _ __ _
<br /> ---
<br /> __ _--- - _----- -- ----- --
<br /> Component Area Sen Lat Sen Total
<br /> Description _ __ Quan Loss _ Gain_ _______Gain _ __ Gain
<br /> LOW EE: Glazing-Builder Grade Low E Windows & 255.2 6,727 0 7,023 7,023
<br /> Sliding Door .33 U value .33 SHGC, u-value 0.31,
<br /> SHGC 0.29
<br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 3304.8 19,101 0 3,909 3,909
<br /> cavity, no board insulation, siding finish, wood studs
<br /> RJ 10 Spray Foam: Wall-Frame, Custom, Closed Cell 228 1,938 0 550 550
<br /> R10 Spray Foam
<br /> 166-44: Roof/Ceiling-Under Attic with Insulation on Attic 3154.7 5,899 0 3,471 3,471
<br /> Floor(also use for Knee Walls and Partition
<br /> Ceilings), Vented Attic, No Radiant Barrier, Dark
<br /> Asphalt Shingles or Dark Metal, Tar and Gravel or
<br /> Membrane, R-44 insulation
<br /> 20P-30: Floor-Over open crawl space or garage, Passive, 53 158 0 19 19
<br /> R-30 blanket insulation, any cover
<br /> 20P-38: Floor-Over open crawl space or garage, Passive, 1055.5 2,691 0 316 316
<br /> R-38 blanket insulation, any cover
<br /> 21A-28: Floor-Basement, Concrete slab, any thickness, 2 715 1,337 0 0 0
<br /> or more feet below grade, no insulation below floor,
<br /> any floor cover,_shortest side of floor slab is 28'wide _ _ __ __ __ _ _
<br /> Subtotals for structure: 37,851 0 15,288 15,288
<br /> People: 0 0 0 0
<br /> Equipment: 0 478 478
<br /> Lighting: 0 0 0
<br /> Ductwork: 289 33 54 87
<br /> Infiltration: Winter CFM: 123, Summer CFM: 54 11,125 1,133 862 1,995
<br /> Ventilation: Winter CFM: 140, Summer CFM: 140 5,080 2,948 896 3,845
<br /> Exhaust: Winter CFM: 100, Summer CFM: 100
<br /> Humidification (Winter) 13,07_gal/day : . 4,794 _ 0 0 0
<br /> System 2 Load Totals: 59,139 4,114 17,579 21,693
<br /> Check Fiqures
<br /> Supply CFM: 782 CFM Per Square ft.: 0.248
<br /> Square ft. of Room Area: 3,155 Square ft. Per Ton: 1,745
<br /> Volume (ft') of Cond. Space: 30,958
<br /> S stem Loads
<br /> Total Heating Required Including Ventilation Air: 59,139 Btuh 59.139 MBH
<br /> Total Sensible Gain: 17,579 Btuh 81 %
<br /> Total Latent Gain: 4,114 Btuh 19 %
<br /> Total Cooling Required Including Ventilation Air: 21,693 Btuh 1.81 Tons (Based On Sensible + Latent)
<br /> Notes
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.�
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> C:\...\Gonyea 125 Kintrye Ln Orono WILSON.rh9 Friday, June 20, 2014, 4:08 PM
<br />
|