Laserfiche WebLink
� � . �Voigt & Associates, Inc. <br /> � STRUCTURAL ENGINEERING SERVICES <br /> 4635 NICOLS RD. SUITE 204 <br /> EAGAN,MN 55122 <br /> � PH. (651)686-7727 FAX. (651)686-8444 <br /> Jon Connolly June 23,2014 <br /> Gonyea Homes <br /> 6102 Olson Memorial Highway <br /> Golden Valley,MN 55422 <br /> 763-432-4507 <br /> jon @ Qonyeahomes.com <br /> RE: Kintyre Model at 125 Kintvre lane,Orono,MN 55391 <br /> Dear Mr.Connelly: <br /> Per your request,I examined the main level garage(right)elevation of the address above for compliance with the Minnesota <br /> State Building Code(2006 IRC)bracing requirements. Your plan notes that you will be sheathing the entire exterior of the <br /> building with OSB (method 3)permitting the use of R602.10.5 Continuous wood structural panel sheathing. Please note <br /> IRC Figure R602.10.5 Typical Exterior Corner Nailing....Stud to Stud Nailing required for the continuous method. The <br /> continuous method permits effective wall lengths as short as 30"for a 10' ceiling adjacent to a window opening. . <br /> The attached sheet,BP-1,indicates the location of braced wall segments for the garage elevation of the main level of this <br /> house and the location of portal frames. See details S 1. <br /> A basic assumption of IRC bracing is that the rest of the structure is properly constructed and connected per the appropriate <br /> section of the code. There is a notable requirement in IRC Table R602.3(1),Fastening Schedule for Structural Members for <br /> braced wall lines. It notes that the connection at the Sole plate to joist or joist blocking nt braced wnll panels be 3- 16d nails <br /> every 16"oc. <br /> Per your request,I examined the stairwell wall on the plan you sent to me for the home at the above address. See Detail T1. <br /> Additionally,per your request,I examined the tall wall at the stairwell on the plan you sent to me for the home at the above <br /> address. See Detail T 1. Frame the tall exterior stud walls of the Sport Court with(2)2X6#2 SPF studs spaced 16"OC. <br /> The information and opinions contained herein are based upon the limited investigation described at the beginning of this <br /> report. No warranties are expressed or implied regarding the existence of other unknown conditions not specifically <br /> addressed. Our work is in accordance with generally accepted engineering standards and is not intended to be relied upon or <br /> transferred to individuals other than the addressee. Should information or conditions become known which differ from the <br /> discussion herein, they may alter the opinions or conclusions of the undersigned. <br /> Please call if you have any questions. <br /> Sincerely, <br /> P�2. � � . <br /> I Hereby Certify That This Plan, Specification,Or Report Was Prepared <br /> By Me Or Under My Direct Supervision And That I Am A Duly <br /> Licensed Engineer Under The Laws Of The State Of Minnesota. <br /> Paul W. Voigt Date 6/23/14 License Number 20705 <br /> �� �111�1�- LAI�-� <br /> 2�J14-OQ(�f� <br />