Laserfiche WebLink
- - -- - - -- ----- ---- <br /> Rhyac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbir,q&Heatinq 125 Kintyre Ln Orono <br /> PI mouth MN 55447 Pa e 4 <br /> ---- - - <br /> -- - - - - <br /> __ _ - - -- --- <br /> S�tem 1 _ Summ� Loads _--- --- ----- _ _ - ___ __ <br /> - -- __ _ _- <br /> - -- - -- <br /> _ _--- <br /> Component Area Sen Lat Sen Total <br /> Description __ Quan __.__ Loss___ Gain_____ Gain___ _ Gain <br /> LOW EE: Glazing-Builder Grade Low E Windows & 447 6 11,792 0 12,911 12,911 <br /> Sliding Door .33 U value .33 SHGC, u-value 0.31, <br /> SHGC 0.29 <br /> 11J: Door-Metal - Fiberglass Core 60 3,060 0 1,044 1,044 <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 1896.4 10,962 0 2,632 2,632 <br /> cavity, no board insulation, siding finish, wood studs <br /> RJ 10 Spray Foam: Wall-Frame, Custom, Closed Cell 646.1 5,492 0 1,748 1,748 <br /> R10 Spray Foam <br /> EXT R-5-9': Wall-Basement, Custom, Rigid R-5 Styro- 1467 24,939 0 0 0 <br /> foam to top of footing- EXTERIOR PERIMETER-9' <br /> basement <br /> EXT R-S-4': Wall-Basement, Custom, Rigid R-5 Styro- 68 1,156 0 0 0 <br /> foam to top of footing- EXTERIOR PERIMETER-4' <br /> wa I I <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 9 27 0 4 4 <br /> R-30 blanket insulation, any cover <br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 2087.1 4,790 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide . __ _ __ __ _ __ _ _ <br /> Subtotals for structure: 62,218 0 18,339 18,339 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 683 2,952 3,635 <br /> Lighting: 0 0 0 <br /> Ductwork: 6,425 1,449 1,610 3,059 <br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 140, Summer CFM: 140 5,080 3,547 1,076 4,623 <br /> AED Excursion: 0 0 386 386 <br /> System 1 Load Totals: 73,723 6,879 25,743 32,622 <br /> Check Fi ures <br /> Supply CFM: 1,156 CFM Per Square ft.: 0.277 <br /> Square ft. of Room Area: 4,174 Square ft. Per Ton: 1,535 <br /> Volume (ft3) of Cond. Space: 39,655 <br /> S stem Loads <br /> Total Heating Required Including Ventilation Air: 73,723 Btuh 73.723 MBH <br /> Total Sensible Gain: 25,743 Btuh 79 % <br /> Total Latent Gain: 6,879 Btuh 21 % <br /> Total Cooling Required Including Ventilation Air: 32,622 Btuh 2.72 Tons (Based On Sensible + Latent) <br /> Notes ' <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Gonyea 125 Kintrye Ln Orono WILSON.rh9 Friday, June 20, 2014, 4:08 PM <br />