<br /> �Load Preview Report
<br /> Net� ft'{ � Sen: Lat+ Netl Sen# Sys_ Sys( Sys� Duct
<br /> Scope Ton��' /Ton�� Area: Gain' Gain; Gain� Loss'�� CFM; CFM� CFM� Size
<br /> ____,_ _ __- ---- .__.. _ __ ___ _---- --- __..--- . __ __ __ ----
<br /> Building 4.53 1,619 7,329 43,321 10,993 54,315 132,862 1,642 1,937 1,937
<br /> System 1 2.72 1,535 4,174 25,743 6,879 32,622 73,723 919 1,156 1,156 12x17
<br /> Ventilation 1,076 3,547 4,623 5,080
<br /> Duct Latent 1,449 1,449
<br /> Zone 1 -CIg.:79%,Htg.:39% 2,087 23,503 1,883 25,386 26,484 354 1,101 1,101 12x16
<br /> 2-Main floor 2,087 23,503 1,883 25,386 26,484 354 1,101 1,101 11--6
<br /> Zone 2-Clg.:21%,Htg.:61% 2,087 6,373 0 6,373 42,159 564 299 299 8x8
<br /> 1-Basement 2,087 6,373 0 6,373 42,159 564 299 299 3-6
<br /> System 2 1.81 1,745 3,155 17,579 4,114 21,693 59,139 724 782 782 10x15
<br /> Ventilation 896 2,948 3,845 5,080
<br /> Duct Latent 33 33
<br /> Humidification 4,794
<br /> Zone 1 -Clg.:83%,Htg.:74% 2,440 14,875 803 15,678 36,399 535 697 697 10x14
<br /> 4-2nd floor 2,440 14,875 803 15,678 36,399 535 697 697 7-6
<br /> Zone 2-Clg.: 17%,Htg.:26% 715 3,076 330 3,406 12,865 189 144 144 5x5
<br /> 3-Sport Court 715 3,076 330 3,406 12,865 189 144 144 2-5
<br /> Sum of room airflows may be greater than system airflow because
<br /> s stem has multi le zones.
<br /> C:\...\Gonyea 125 Kintrye Ln Orono WILSON.rh9 Friday, June 20, 2014, 4:08 PM