My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-00685 - new structure
Orono
>
Property Files
>
Street Address
>
K
>
Kintyre Lane
>
125 Kintyre Lane - 32-118-23-43-0017
>
Permits/Inspections
>
2014-00685 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:41:53 PM
Creation date
4/12/2017 9:00:34 AM
Metadata
Fields
Template:
x Address Old
House Number
125
Street Name
Kintyre
Street Type
Lane
Address
125 Kintyre Lane
Document Type
Permits/Inspections
PIN
3211823430017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residentiai&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> SabrP Plumbii�q&Heatinq 125 Kintyre Ln Orono <br /> PI mouth�MN 55447 _ ____ ______ ____ Pa e2 <br /> _--- -- - ----- -- . <br /> _ -_ _---- -- - -- <br /> Project Report _ _ ___ � <br /> General Pro'ect information <br /> Project Title: 125 Kintyre Ln Orono <br /> Designed By: Todd Boyum <br /> Project Date: 6/20/14 <br /> Client Name: Gonyea Homes <br /> Client City: Golden Valley, MN <br /> Company Name: Sabre Plumbing & Heating <br /> Company Representative: Todd Boyum <br /> Company Address: 15535 Medina Rd <br /> Company City: Plymouth, MN 55447 <br /> Company Phone: 763-473-2267 <br /> Company Fax: 763-473-8565 <br /> Qesign Data <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> � Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -15 -12.38 n/a n/a 70 n/a <br /> Summer: 90 73 45% 50% 72 38 <br /> ��Check Figures � � s���� <br /> Total Building Supply CFM: 1,937 CFM Per Square ft.: 0.264 <br /> Square ft. of Room Area: 7,329 Square ft. Per Ton: 1,619 <br /> Volume (ft3) of Cond. Space: 70,613 <br /> Buildinq Loads <br /> Total Heating Required Including Ventilation Air: 132,862 Btuh 132.862 MBH <br /> Total Sensible Gain: 43,321 Btuh 80 % <br /> Total Latent Gain: 10,993 Btuh 20 % <br /> Total Cooling Required Including Ventilation Air: 54,315 Btuh 4.53 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Gonyea 125 Kintrye Ln Orono WILSON.rh9 Friday, June 20, 2014, 4:08 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.