A non-structural steel special inspection final report-2015
Orono
>
Property Files
>
Street Address
>
K
>
Kelley Parkway
>
2730 Kelley Parkway - 33-118-23-12-0007
>
Misc
>
A non-structural steel special inspection final report-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:43 PM
Creation date
3/28/2017 11:58:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2700
Street Name
Kelley
Street Type
Parkway
Address
2700 Kelley Parkway
Document Type
Misc
PIN
3311823120007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br /> sRauN <br /> INTERTEC <br /> Special Inspection Daily Report <br /> Clty Of OfOno Page: 1 of 1 <br /> Report No.: #32 Dafe: December 4,2014 <br /> Projed Name: Orono Police Dept.Expansion Pro)ect No.: 614-05902 <br /> Project Address: 2730 Keliy Pkwy. Braun Intertec PM: MARK FLYNN <br /> Client City of Orono Client Project No.: <br /> Weather: Parfly Cloudy Temperature: 20°F <br /> Type of Inspection: Inspection Coverage: <br /> ❑ Continuous �Masonry � Rebar Placement ❑ Foundations ❑Special Cases <br /> � Periodic ❑Welding&Bolting ❑Concrete ❑ Fireproofing <br /> ❑ Piles 8�Piers ❑Tendon Placement ❑Soils <br /> Did the architect or engineer authorize changes to approved plans� Yes❑ (Listed Below) No � <br /> Descdption and locafion of work compiefed: <br /> -Observed the placement of rebar and grout for masonry wall @ Grid C.6 to D from 5.4 to 6 at elevation 104'and <br /> masonry wall�Grid A-5.7 to 8-5.7 at elevation 104'. <br /> lisf tests perfortned: <br /> I <br /> • Are there any discrepancies noted from this day's observations� Yes ❑ No � <br /> . Are there any outstanding discrepancies on this project8 Yes ❑ No � <br /> . If yes,see attached Summary Sheet. <br /> • Reporf Discussed with and Given to Contractor: Yes � No ❑ <br /> Report Emalled to: <br /> Jack Broncryk-jqck.brnnczyk@krausanderson.com <br /> To the best of our knowledge,work inspected was done in accordance with the approved plans,spec'rfications and <br /> applicable workmanship provisions of the current IBC,except as noted above. <br /> a� Loosbrock, Tom <br /> I.D.No.: 1136593 <br /> -Prouiding engineering and enuironmenta(solu�ions since 1957 <br />