Laserfiche WebLink
/% 0 � <br /> �: � � <br /> , <br /> '�O O�, <br /> '' '�'� CITY of ORONO <br /> �� � �� ���r:,�� <br /> � . � ; <br /> ��, r�,, 1 ���`�'�,� . ��l4;� Municipat offices <br /> � '� , <br /> ��,, .� ���. �� �'.� � Street Address: Mailing Address: <br /> V��C'�gg0�' % 2750 Kelley Parkway P.O. Box 66 <br /> � - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> �„�.. <br /> Owner��' �� Address:3155 Jamestown Rd. <br /> Permit #'s:4894418 Dates:8/1/77, 2,20,92 Contractors:Gene Hayes, E. J. Peterson <br /> (This is ,j/,}� an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant Svstem: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br />�� Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level [xj has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision. ) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpc�ut not needed at this time <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br />�9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> `"` tanks have not been um ed out within three ears the should be <br /> P A y , y pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the a ks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION 11-14 : 11 <br />�1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system acTe and condition, soils etc. ) : medium <br /> COMMENTS: T'he non-conformin se tic s stem must be re aired 31 96.. <br /> �=��.-��� �� � ` �- '. ; ,-�., <br /> Date of Insp ction Se i System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />