Laserfiche WebLink
DIVISION 7 - MOISTURE PROTECTION <br /> A. Bituminous Dampproofing: Foundation walls below grade to be dampproofed with <br /> Tuff-N-Dri. Interior-Exterior drain tile system to be installed. <br /> B. Insulation <br /> 1. Rigid Insulation: Styrofoam conforming to Fed. Spec. HH-152-YC. <br /> 2. Fiberglass Insulation: Unfaced fiberglass conforming to Fed. Spec. HH-1-521 <br /> Type 1. R-19 Exterior walls. <br /> 3. Blown Insulation: Fiberglass insulation conforming to Fed. Spec. HH1-1-10306, <br /> Type 1 Class A. R-60 ceilings. <br /> C. Vapor Barrier <br /> 1 . Provide 6 mil. poly. vapor barrier for exterior walls and ceilings. <br /> D. Shingles <br /> 1. Shingles to be hand split cedar"medium" shakes. <br /> 2. Flashings: Valley, eave and rake flashings to be 24 ga. galvanized metal. <br /> E. Sealants: Caulking to be silicone based. <br /> F. Plumbing walls and stacks to be insulated. <br /> DIVISION 8 - DOORS. WINDOWS AND GLASS <br /> A. Windows to be Kolbe - Kolbe primed casement in sizes shown. Refer to plans for <br /> fixed and special size windows. <br /> B Patio doors and terrace (French) doors to be Kolbe - Kolbe primed, in sizes shown. <br /> C. Sliding glass patio doors shall be Pella primed, in sizes shown. <br /> D. Interior doors to be 6 panel pine, hemlock or fir, depending on availability, as made by <br /> Nord or equal. <br /> E Finish hardware shall match the existing hardware. <br /> F. Mirrors and Glass: Full size mirror and tempered glass shower door as shown in the <br /> lower level bathroom. <br />