My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P08409 - new structure
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2618 Casco Point Road - 20-117-23-24-0038
>
Permits/Inspections
>
2005-P08409 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:55:26 PM
Creation date
3/9/2016 1:40:48 PM
Metadata
Fields
Template:
x Address Old
House Number
2618
Street Name
Casco Point
Street Type
Road
Address
2618 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240038
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, Page 3 of 6. NER-604 <br /> Design calculations and details for specific applications shall 4.4 Wood Construction in Areas of Very Heavy <br /> be furnished to the code official verifying compliance with this Termite Infestation <br /> report and the applicable Code. The individual preparing <br /> such documents shail possess the necessary credentials In jurisdictions that have adopted the Standard Building <br /> regarding competency and qualifications as required by the CodeO International One and Two Family Dwelling Code, <br /> applicable Code and the professional registration laws of the and the International Residential CodeT"', where foam <br /> state where the construction is uncfertaken. plastic insulation is used with wood construction in areas of <br /> very heavy termite infestation, the foam plastic shall be <br /> 4.3.2 Reward Wall System eFORMT""forms are defined installed in accordance with sections 1916.7.5 and 2603.3 <br /> as Waffle-Grid insulating concrete form wall systems and are of the Standard Building CodeO, Section 323.4 of the <br /> designed and reinforced using the load tables for Waffle-Grid International One and Two Family Dwelling Code and <br /> ICF forms in sections 1916 and 1804.6.2 of the Standard Section R324.4 of the International Residential CodeT"^ <br /> Building CodeO(SBC) or sections R404.4 and R611 of the Areas of very heavy termite infestation shall be determined in <br /> International Residential CodeO(IRC) provided the building accordance with Figure 2304.1.4 SBC, Figure 301.2(6) <br /> conforms to the applicability limits defined in Sections 1916.2 11&2FDC and Figure R301.2(6)IRC. <br /> and 1804.6.2.1 of the SBC or Sections R404.4.1 and R611.2 <br /> of the IRC.When using this prescriptive design method,the 4.5 Fire Resistive Rated Wall Assemblies <br /> wall thickness is limited as noted in the applicable code <br /> sections referenced above. Reward Wall System forms were fire tested under ASTM E <br /> 119 as fire resistance rated bearing and non-bearing wall <br /> When the Waffle-Grid ICF forms are installed on buildings assemblies. The assemblies shall have the hourly fire <br /> that do not conform to the applicability limits of Sections resistance ratings and shall be installed as shown in the <br /> 1916.2 and 1804.6.2.1 of the SBC or Sections R404.4.1 and Table 1 of this report. <br /> R611.2 of the IRC, the structural analysis and design of the <br /> concrete shall be prepared in accordance with ACI 318 and Walls exposed to the e�erior shall be finished with a weather <br /> Chapter 19 of the Standard Building CodeO, International resistive barrier such as stucco or brick veneer or other <br /> Building CodeO, BOCA National Building Code,or Uniform approved siding or veneer installed in accordance with the <br /> Building Code or Section R611 of the International appiicable Code. <br /> Residential CodeO,as applicable. <br /> 4.6 Installation in Buildings of Noncombustible <br /> eFORMS are also permitted to be designed and reinforced Construction <br /> in accordance with Section 6 of the Reward Walls Installation, <br /> Structural Technical Manual,referred to in Section 6.2 of this The forms are permitted to be used in buildings of <br /> report. noncombustible construction when installed as follows: <br /> 4.3.3 Reward Wall System iFORMT"" forms are defined 4.6.1 Exterior Walls of Buildings of Any Height: The <br /> as Flat insulating concrete form wall systems and are following conditions shall appty: <br /> designed and reinforced using the load tables for Flat ICF <br /> forms in Sections 1916 and 1804.6.2 of the Standard Building 4.6.1.1 EIFS and One Coat Stucco-Exterior Finish:The <br /> CodeO or Sections R404.4 and R611 of the International following EIFS and One Coat Stucco Wall Finishes are <br /> Residential CodeO provided the building conforms to the installed over the exterior of the forms using the Reinforcing <br /> applicability limits defined in Sections 1916.2 and 1804.6.2.1 Fabric, base coat and finish coat materials described in their <br /> of the SBC or sections R404.4.1 and R611.2 of the IRC. Code evaluation reports. <br /> When using this prescriptive design method, the wall <br /> thickness is limited as noted in the applicable code sections • W,R. Bonsal Company, Flex Surewall System <br /> referenced above. EIFS as described in SBCCI PST&ESI Evaluation <br /> When the Flat ICF forms are installed on buildin s that do not Report #95606 and BOCA ES Research Report <br /> 9 #98-47. <br /> conform to the applicability limits of Sections 1916.2 and • RETRO TEK Soft Coat System PB and Hard Coat <br /> 1804.6.2.1 of the SBC or Sections R404.4.1 and R611.2 of System PM EIFS as described in SBCCI PST&ESI <br /> the IRC, the structural analysis and design of the concrete Evaluation Report#96386 and BOCA ES Research <br /> shall be prepared in accordance with ACI 318 and Chapter Report#97-28. <br /> 19 of the Standard Building CodeO, International Building • Dryvit Systems, Inc., Outsulation System as <br /> CodeO,BOCA National8uilding Code,or Uniform Building described in SBCCI PST & ESI Evaluation Report <br /> Code or Section R611 of the International Residential #94176A and BOCA ES Research Report#96-38- <br /> CodeO,as applicable. p� <br /> • Senergy Inc., Senerflex EIFS as described in <br /> iFORMS are also permitted to be designed and reinforced SBCCI PST & ESI Evaluation Report#9630A and <br /> in accordance with Section 6 of the Reward Walls Installation, BOCA ES Research Report#97-86. <br /> Structural Technical Manual,referred to in Section 6.2 of this • Sto Corp., Sto EIF Classic System Class PB <br /> report system as described in SBCCI PST & ESI <br /> Evaluation Report #94150C and BOCA ES <br /> 4.3.4 Prescriptive Design of ICF by PCA Pub. EB118: Research Report#97-14. <br /> The eFORMS and iFORMS are also permitted to be designed • Sonneborn/ChemRex Inc., Sonneborn Flex Wall <br /> and reinforced in accordance with Prescriptive Method for Stucco System EIFS as described in SBCCI PST& <br /> Insulating Concrete Forms in Residential Construction, PCA ESI Evaluation Report#2028. <br /> publication EB118 provided the building conforms to the • W.R. Bonsal Company, One Coat Stucco <br /> applicability limits defined in Table 1.1 of the Prescriptive Systems,Surewall FRP as described in SBCCI PST <br /> Method. & ESI Evaluation Report #9908 and BOCA <br /> Research Report#98-48. <br /> • Omega Products International, Inc., Omega <br /> Akroflex as described in BOCA Research Report <br /> #98-49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.