My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P08409 - new structure
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2618 Casco Point Road - 20-117-23-24-0038
>
Permits/Inspections
>
2005-P08409 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:55:26 PM
Creation date
3/9/2016 1:40:48 PM
Metadata
Fields
Template:
x Address Old
House Number
2618
Street Name
Casco Point
Street Type
Road
Address
2618 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240038
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 6 NER-604 <br /> report for fire-resistive-rated assemblies. concrete is prepared in accordance with the manufacturer's <br /> recommended design procedure,ACI 318 and the applicable <br /> 3.2.4 Reinforcement: Deformed steel reinforcing bars, Code;see Section 4.3 of this report. <br /> complying with the applicable Code, with a minimum yield <br /> stress of either 40 ksi (275 kPa) or 60 ksi (413 kPa), The Reward Wall System0 shall be finished on the interior of <br /> depending on the structural design. the building with an approved 15 minute thermal barrier,such <br /> as minimum '/2 inch thick (12.7 mm) regular gypsum <br /> 3.2.5 Other components:Wood members in contactwith wallboard attached to the plastic cross tie fastener strips. The <br /> concrete for plates or windows and door framing shall be minimum Y2 inch thick(12.7)regular gypsum wallboard shall <br /> preservative treated with an approved wood preservative,or be installed vertically and attached to the plastic cross-tie <br /> naturatly durable species and shall be attached with fastener strips with 0.152 inch diameter by 1.5 inch long(3.9 <br /> galvanized steel anchor bolts complying with the applicable mm by 38 mm) coarse thread gypsum wailboard screws <br /> Code.Materials other than wood,such as vinyl,are permitted spaced 12 inches(305 mm)on center in the field of the board <br /> for window and door framing if approved by the code official. and 8 inches on center at the perimeter. Crawl space <br /> installation is discussed in Section 4.2 below. <br /> 3.3 Standard and Accessory Forms <br /> Reward Wall Systems0 forms shall be covered on the <br /> 3.3.1 eFORMS exterior with a weather-resistive barrier and an approved wall <br /> • Standard Forms 9-1/4 and 11 inch covering complying with the applicable Code or listed in an <br /> •Right Hand 9-1/4 and 11 Inch Corner Forms(long NES, SBCCI PST & ESI or BOCA International, Inc. <br /> leg 36 inches, short leg 12 inches) Evaluation Report.The wall covering shall be attached to the <br /> • Left Hand 9-1/4 and 11 Inch Corner Forms(long plastic cross-tie fastener strips with coarse thread drywall <br /> leg 36 inches,short leg 12 inches) screws. The screws shall be corrosion resistant and have <br /> .45°corner unit 9-1/4 inch sufficient length to penetrate the plastic cross-tie fastener <br /> strips a minimum of 1/4 inch (6.4 mm). The screws shali <br /> 3.3.2 iFORMS have an allowable pullout and lateral capacity of 70 pounds <br /> • Standard Forms 9, 11 and 13 inch universal(No (311 N). Negative wind pressure capacity of the exterior <br /> top, bottom, left or right) finish material shall be the same as that recognized in the <br /> • One universal 9 inch 90 degree corner form for applicable Code for the generic finish material or as listed in <br /> both left and right hand corners(Long leg 25 inches, the current NES,SBCCI PST&ESI or BOCA International, <br /> short leg 13 inches)(No top, bottom, left or right). �nc. Evaluation Report. <br /> • One universal 11 inch 90 degree corner form for <br /> both left and right hand corners(long leg 27 inches, For basement wall installations Reward Wall System form <br /> short leg 15 inches)(No top, bottom, left or right). surfaces shall be waterproofed in accordance with the <br /> • One universal 13 inch 90 degree corner form for applicable Code. The waterproofing materials shall be <br /> both left and right hand corners(long leg 29 inches, approved by Reward Wall Systems,Inc.and the code official, <br /> short leg 17 inches). (No top, bottom, left or right) and shall be free of solvents, hydrocarbons, ketones and <br /> • 45 degree corner form for the 9, 11 and 13 inch esters that will adversely affect the EPS foam. No backfill is <br /> forms. (No top, bottom, left or right) permitted to be applied against the wall until the complete <br /> flooring system is in piace. <br /> 3.4 Surface Burning Characteristics <br /> The manufacturer's published instailation instructions and this <br /> The polystyrene foam plastic used in the manufacture of the report shall be strictly adhered to and a copy of these <br /> Reward Wall Systems0 forms was tested for surface burning instructions shall be available at all times on the job site <br /> characteristics under ASTM E 84 to a maximum thickness of during installation. The instructions within this report govern <br /> 2.5 inches(63.5 mm)and demonstrated a flamespread index �f there are any conflicts between the manufacturer's <br /> FSI of 25 or less and a smoke development index SDI of 450 Published installation instructions and this report. <br /> or less. 4.2 Crawl Space Installation <br /> 3.5 Crawl Space Fire Evaluation <br /> The Reward Wall Systems0 forms are permitted to be <br /> The polystyrene foam plastic by BASF Corporation, �nstalled exposed in a crawl space without a thermal barrier <br /> Huntsman Corporation and NOVA Chemicals,Inc.used in the under the following conditions: <br /> manufacture of the Reward Wail Systems0 forms was fire <br /> tested in a full scale crawl space construction. The crawl 4.2.1 Entry to the crawl space is limited to service of <br /> space was constructed with masonry block walls covered with utilities; <br /> 3 inch(76.2 mm)thickness of polystyrene and a wood framed 4.2.2 There are no interconnected basement areas; <br /> floor construction. A 22 Ib (11 kg) crib was ignited in the 4.2.3 Air in the crawl space is not circulated to other parts <br /> crawl space. Installation in crawl spaces shall be in of the building; <br /> accordance with Section 4.2 of this report. 4.2.4 Ventilation of the crawl space is provided in <br /> accordance with the applicable Code. <br /> 4.0 INSTALLATION 4.2.5 Crawl space installation shall be limited to forms <br /> expanded from beads manufactured by BASF <br /> 4.1 Generat Corporation, Huntsman Chemical Corporation and <br /> NOVA Chemicals, Inc. <br /> Reward Wall Systems0 forms are installed in accordance <br /> with the manufacturer's published installation instructions and 4.3 Design <br /> this report. <br /> 4.3.1 General The Reward Wall System forms are <br /> The Reward Wall Systems0 forms are installed as formwork installed as formwork for foundation and basement load <br /> for either load bearing or non-load bearing walls for bearing and non-load bearing walls and exterior load bearing <br /> residential and commercial construction. These walls include and non-load bearing walls for residential and commercial <br /> foundations, basements and above grade walls and interior construction. <br /> or exterior walls. Structural analysis and design of the <br />
The URL can be used to link to this page
Your browser does not support the video tag.