41. Not less than 3 studs shall be installed at every corner of an exterior <br />wall, unless other approval by Building Official. Sec. 2517-g-2. <br />42. Studs in bearing and exterior walls shall be capped with double <br />plates, installed to provide over -lapping <tt corners and partitions. Sec. <br />2517-g-2. <br />43. End joints in double plats shall be offset a minimum of 48". Sec. <br />2517-g-2. <br />44. All exterior walls and main cross partitions shall be effectively and <br />thoroughly braced at each end, and at least every 25 feet in length. <br />Sec. 2517-g-3. <br />45. Foundation cripple walls shall be framed of studs not less insize than <br />the studding above with a minimum length of 14 inches, or shall be fr�.es <br />of solid blocking. Sec. 2517-g-4. <br />46. All headers or lintels shall have not less than 2" solid bearing a, <br />each end to the floor or bottom plats. Sec. 2517-g-5. <br />47. All stud partitions in the basement that are not covered on at least <br />one side with approved wall coverings shall be braced with 2" thick <br />bridging installed at mid -point of wall, and of the same width as the stud. <br />Sec. 2517-g-7. <br />48. Rafters shall be framed directly opposite each other at the ridge. <br />Ridge board shall be a minimum of 1" in thickness and not less in depth <br />than the cut end of the rafter. (2" larger than rafter) Sec. 2517-h-3. <br />49 All lumber, plywood, etc. shall be identified by the grade mark of an <br />apL.;roved agency. Sec. 2505. <br />50. In the one hour occupancy separation between a Group R and M <br />occupancy, the separtion may be limited to the installation of materials <br />approved for one hour fire resistive construction on the garage side and a <br />self -closing, tight -fitting solid wood door 1 3/8" in thickness will be <br />permitted. Sec. 503-d-4. <br />51. Fire stoppings shall be provided to cut off all concealed draft <br />openings (both vertical and horizontal). Sec. 2516-f. <br />LIFE, SAFETY, AND HEALTH <br />52. Every sleeping room below the fourth floor shall have at least one <br />window or exterior door approved for emergency exit. windows with a net <br />clear openable area of not less than 5.7 sq. ft. min. net clear opening <br />height 24" width 20", with a max. sill height above the floor of 48" shall <br />be deemed to meet this requirement. Sec. 1204. <br />NOTE: The minimum dimensions do not meet 5.7 sq. ft. <br />53. All habitable rooms shall have natural light provided by window, with <br />an area of not less than 8% of f loor area or min. of 8 sq. frt. Sec 1205. <br />(1/20 of the above small be openable or a min. of 5 sq. ft.) *Exception. A <br />