mechanical ventilation system may be provided which will provide 2 air <br />changes per hour. 1/5 shall be outside air. <br />54. All bathrooms, laundry rooms etc. shall have 1/20 of floor are in <br />glass with a min. of 1 1/2 sq. ft. Sec. 1205. *Exception. A mechanical <br />ventilation system may provided which will provide 5 air changes per hour. <br />55. For the purpose of determinini light and ventilation requirements, any <br />room may be considered as portion of an adjoining room when 1/2 of the area <br />of the common wall is open and unobstructed and provides an opening of not <br />less than 1/10 of the floor area of the interior room or 25 sq. ft., <br />whichever is greater. Sec. 1205-a. <br />56. Ceiling heights in habitable rooms, shall be not less thr- 7' 6". <br />Other rooms may have ceiling height of not less than 7' measured to lowest <br />projection. Sec. 1207-a. <br />57. Every dwelling unit shall have at least one room which shall nave not <br />less than 150 sq. ft. of floor are. Other habitable rooms except kitchens <br />shall have an area of not less than 70 sq. ft. Sec. 1207-b. <br />58. No habital room shall hava a width of less than 7 ft. except a <br />kitchen. Sec. 1207-c. <br />59. A water closet compartment shall be not less than 30 inches in width <br />and shall provide a clear space in front of the water closet not less than <br />24'. Sec. 511-a. <br />60. Every dwelling unit shall be provided with an approved smoke detector <br />conforming to UBC Std. i43-6. They shall be mounted on the ceiling or a <br />wall at a point centrally located in the corridor or area giving access to <br />rooms used for sleeping purposes. All detectors shall be located within <br />12" of the ceiling. Sec. 1210-a. <br />61. Every dwelling unit shall be provided with heating facilities capable <br />of maintaining a room temperature of 70 degrees at a point 3 ft above the <br />floor in all habitable rooms. Sec. 1211. <br />62. All weather exposed surfaces, shall have a weather resistive barrier <br />to protect the interior wall. Sec. 1707-a. <br />63. Exterior openings exposed to the weather shall be flashed in such a <br />manner as to make them weatherproof. Sec. 1707-b. <br />64. All flashing, counter flashing, and coping when of metal shall be not <br />less than 126 gauge corrosion resistant metal. Sec. 1707-b. <br />65. Shower areas shall have a smooth, hard nonabsorbent surface such as <br />ceramic tile, to a height of not less than 6 feet. Materials other than <br />structural elements used in such walls shall be of a type not adversely <br />affected by moisture. Sec. 510-b. <br />66. Glazing used in door ad panels of shower and bathtub enclosures shall <br />be fully tempered, laminated saftey glass, or approved plastic 3/16, min. <br />thickness when fully tempered or 1/4' when laminated. Sec. 5406-c-d. <br />