Laserfiche WebLink
buildings range from 1023’ to 1025’. The overall site will maintain a similar grade to the existing lot. <br />The buildings are proposed to have a 39.5-foot peak height (measured from the first-floor elevation to <br />the top of the gable) and measure 31.75 feet to the midpoint of the roof. With the minimal grading <br />required for the site, staff anticipates the defined height (grade to the midpoint of a gabled roof) to be <br />approximately 32 feet. The proposed development will conform to the 40’ defined height maximum. <br />Section 78-826 –Building Design and Construction: <br />(5) Long Facades: Where large structures with overly-long facades (walls) are proposed, such as <br />warehouses, building mass should be articulated with variations in the building plane and <br />parapet height and through the use of other unique design or site plan features. The applicant <br />has proposed roof gables to break up the roof mass and create interest along the roofline. <br />Windows and/or wall breaks are proposed on the sides of the buildings. <br />(6) Architectural design: Architectural design should create harmony through the use of <br />different textures, complementary colors, shadow lines and contrasting shapes. The use of walls <br />in a single color, with little detailing or completely blank is discouraged. <br />The proposal shows a mix of materials including stone, stucco, siding, and shingles. The colors <br />are charcoal grey/brown with a light stone accent and a black roof. <br />(9) Building Materials:Use of substantial amounts of high-quality masonry materials (face brick, <br />stucco, stone) is encouraged. Buildings shall be constructed with no less than 67 percent of <br />these materials, excluding window and door areas. Evaluation of building materials shall be <br />based on the quality of its design and relationship and compatibility to building materials in the <br />immediate neighborhood. <br />The applicant is proposing to use brick and stucco on each building in combination to meet the <br />67% high-quality material requirement. The remaining percentage will be made up of a cement- <br />board siding material finished in a similar color to match the exterior. <br />Section 78-827 Off-Street Parking: <br />(d) Required Parking: (See Further Analysis under April 14, 2025 City Council Meeting, Exhibit C) <br />The current plan anticipates parking within each individual unit and allows for loading and parking <br />directly in front of each unit. The applicant’s business model indicates that each individual unit will <br />accommodate the necessary parking for each owner. <br />The City Code does not list a parking standard associated with the garage condo use. The <br />applicant is not proposing any outdoor parking. Because the use specifically involves interior <br />parking spaces, Staff applied the following provision: City Code Sec. 78-827(d) (3) Multi-tenant <br />industrial buildings: “One space for each 400 square feet of gross floor area, or the sum of the <br />component gross floor areas as follows, whichever is greater”. Based on this provision, a total of <br />235 parking spaces should be provided; each unit would need to provide 2.7 parking spaces to <br />conform. As designed, each unit would support 2-4 enclosed parking spaces; 60 of the larger- <br />sized units would support 4 cars (240 spaces) and 25 smaller units would support 2 parking <br />spaces (50 spaces). This results in a total of 290 indoor spaces for the site exceeding the <br />calculated requirement. <br />Additionally, the site layout allows for loading and parking directly in front of each unit. It is <br />100