Laserfiche WebLink
Zoning File #1396 <br />April 14, 1989 <br />Page 5 of 6 <br />Drainage - <br />The City Engineer has reviewed the storm water run-off from the site <br />and the proposal. The applicant is proposing a retention pond at the south <br />end of the parking lot. The City Engineer's comments are as follows: <br />1. The parking lot grading plans should be modified to provide a <br />minimum 1% grade. <br />2. The area between the parking lot and the lake should be a minimum <br />of 6" higher than the parking lot. <br />3. The pre-cast concrete bumper curbs should be required around the <br />parking lot. <br />4. The parking lot should be paved to minimize the run-off of silt <br />into the ponding area. <br />5. The proposed drainage plan and ponding area is generally adequate. <br />He also states that with the above corrections, it would provide some <br />protection from the proposed drainage system plugging up. <br />Screening - <br />Screening will be required around the dumpster. <br />Signage - <br />No new signage is proposed. <br />On existing survey, underground fuel storage tank is shown. Applicant <br />must remove underground storage tank or verify that it already has been <br />removed . <br />Dock Access - <br />West side - Access to dock must be maintained every 300' maximum. <br />Fire Extinguishers - <br />Having a 20-B:C rating shall be provided as follows: <br />1 on each float and 1 on the pier or warf 25* at the head of the <br />gangway to float, pursuant to Uniform Fire Code Section 79.911 E. <br />Electrical Equipment - <br />All electrical equipment installed and used must be in accordance with <br />the National Electrical Code as it applies to wet, damp or hazardous <br />locations.