My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986-10-02 Plan Review
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2150 Colin Drive - 03-117-23-21-0015
>
Permits/Inspections
>
1986-10-02 Plan Review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 10:33:12 AM
Creation date
2/20/2025 10:14:13 AM
Metadata
Fields
Template:
x Address Old
House Number
2150
Street Name
Colin
Street Type
Drive
Address
2150 Colin Drive
PIN
0311723210015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN REVIEW - 95 SOUTH BROWN ROAD <br />October 2, 1986 <br />Page 5 <br />49. All headers or lintels shall have not less than 2" solid bearing <br />at each end to the floor or bottom plats. Sec. 2517-g-5. <br />50. All stud partitions in the basement that are not covered on at <br />least one side with approved wall coverings shall be braced with 2" <br />thick bridging installed at mid-point of wall, and of the same width <br />as the stud. Sec. 2517-g-7. <br />51. Rafters shall be framed directly opposite each other at the <br />ridge. Ridge board shall be a minimum of 1" in thickness and not less <br />in depth than the cut end of the rafter. (2" larger than rafter) Sec. <br />2517-h-3. <br />52. Purlins may be installed to reduce the space of rafters within <br />the allowable limits and shall be supported by struts to bearing <br />walls. Sec. 2517-h <br />53. All lumber, plywood, etc. shall be identified by the grade mark <br />of an approved agency. Sec. 2505. <br />54. In the one hour occupancy separation between a Group R and M <br />occupancy, the separtion may ie limited to the installation of <br />materials approved for one hour fire resistive construction on the <br />garage side and a self-closing, tight-fitting solid wood door 1 3/8" <br />in thickness will be permitted. Sec. 503-d-4. <br />55. Fire stoppings shall be provided to cut off all concealed draft <br />openings (both vertical and horizontal). Sec. 2516-f. <br />LIFE, SAFETY, AND HEALTH <br />56. Every sleeping room below the fourth floor shall have at least <br />one window or exterior door approved for emergency exit. Windows with <br />a net clear openable area of not less than 5.7 sq. ft. min. net clear <br />opening height 24" width 20", with a max. sill height above the floor <br />of 48" shall be deemed to meet this requirement. Sec. 1204. <br />NOTE: The minimum dimensions do not meet 5.7 sq. ft. <br />57. All habitable rooms shall have natural light provided by window, <br />with an area of not less than 88 of f loor area or min. of 8 sq. frt. <br />Sec 1205. (1/20 of the above shall be openable or a min. of 5 sq. <br />ft.) *Exception. A mechanical ventilation system may be provided <br />which will provide 2 air changes per hour. 1/5 shall be outside air. <br />58. All bathrooms, laundry rooms etc. shall have 1/20 of floor are in <br />glass with a min. of 1 1/2 sq. ft. Sec. 1205. *Exception. A <br />mechanical ventilation system may provided which will provide 5 air <br />changes per hour. <br />