1986-10-02 Plan Review
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2150 Colin Drive - 03-117-23-21-0015
>
Permits/Inspections
>
1986-10-02 Plan Review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 10:33:12 AM
Creation date
2/20/2025 10:14:13 AM
Metadata
Fields
Template:
x Address Old
House Number
2150
Street Name
Colin
Street Type
Drive
Address
2150 Colin Drive
PIN
0311723210015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN REVIEW - 95 SOUTH BROWN ROAD <br />October 2, 1986 <br />Page 10 <br />102. Vent connectors made of single wall metal pipe shall not pass <br />through any combustible walls unless they are guarded at the point of <br />passage by ventilated metal thimbles. See Sec. 7408 SBC for <br />requirements <br />103. In an individual duct system, such duct shall be provided with a <br />volume damper with substantial mounting and positive locking device. <br />Sec. 7508 SBC <br />104. In a trunk system, each branch duct shall be provided with a <br />splitter damper where it leaves the main trunk duct, and with <br />additional splitter dampers if again divided. All dampers shall be <br />provided with positive locking devices. Sec. 7508 SBC <br />105. Warm air supply ducts shall not be installed for the purpose of <br />heating attached private garages from any forced air system serving <br />habitable areas. Sec. 7508 SBC <br />106. Supply registers shall be securely fastened to connecting pipe. <br />Return air registers shall have a free area at least equal to the free <br />area of the ducts to which they are connected. Sec. 7509-7510 SBC <br />107. Underground ducts installations shall be in accordance with SBC <br />7726. <br />108. In residential installations the fan or blower housing shall not <br />be directly connected with metal either to the furnace casing or to <br />the return air piping. Canvas strips may be used to make these <br />connections. Motors shall be mounted in such a way that vibration <br />will not be transmitted to duct work or equipment. Sec. 7518 SBC <br />109. Residential ventilation, all ducts, (range hood ventilation) <br />shall be galvanized iron of not less than #28 gauge. All seams in the <br />duct system shall be tight. Pressure sensitive tape may be used (if <br />approved). <br />Back draft dampers shall be provided near the outlet of the duct. <br />1/2' mesh screen shall be installed at each exhaust outlet. <br />Ducts passing through unheated spaces shall be insulated with a <br />minimum of one inch of fiber glass insulation. <br />Ducts located in a heated space shall be insulated with one inch of <br />fiber glass insulation for a distance of three feet from the duct <br />outlet. Sec. 7715 SBC <br />110. Combustion air as required by SBr 7722 shall be provided. Air <br />intakes shall be provided from the exterior of the building. <br />