Laserfiche WebLink
Zoning File #2108 <br />February' 14,1996 <br />Page 3 <br />is included in one contiguous parcel and both murucipal sewer and legal access is available <br />to that building site without encroachment on the protected area." In the final plat. Lot 3 <br />must be assured of */j acre dry contiguous building site to the east of the ravine and the access <br />drive must not encroach the ravine area. <br />Major portions of this property drains to the south and east through Lot 5 to a less dramatic <br />ravine area that drains under W'iMhurst Trail to a low/wetland area that eventually drains to <br />the lake. As the Engineer's report notes. E.xhibit H, both drainageways have a high potential <br />for erosion. The City will require storm water ponding to reduce the runoff flows and <br />velocities leaving the site. The applicant must provide drainage and ponding calculations <br />that should include a skimmer structure at pond outlet. This information must be submitted <br />with the preliminary plat application. The City Engineer recommends that the grading and <br />drainage plans be submitted to the Minnehaha Creek Watershed District for their review at <br />the time the preliminary plan is submitted to the City. <br />Grading plans submitted with the formal application must include existing and proposed 2’ <br />contours. The plans must include the following: <br />- Erosion control. <br />Building pad locations and elevations. <br />Location of bluff impact zone and required setback from defined top of bluff. <br />Temporary erosion control during construction. <br />There are no designated wetlands within the seven acre property. The major ravine and <br />drainage way at the northern portion of the property was never designated on the City's <br />wetland maps. <br />Utilities. Sanitary sewer is available to this property'. Water service will be provided by on­ <br />site wells. Refer to Exhibit C, sanitary' sewer w ill be extended approximately 310' north to <br />the intersection of Wildhurst and the private road. The Engineer has asked the City to <br />consider three options concerning current access and sewer to the seven acre site and future <br />service to landlocked properties to the west and north of the subject property. Refer to <br />Exhibits B and I, the Engineer recommends that the southern portions of unimproved Garden <br />Lane be vacated and replatted within the seven ..ere parcel providing direct access to the <br />undeveloped parcels to the north and west via newly realigned Garden Lane. Sewer <br />easements can be extended to the western boundaries of the property so that future sewer <br />service can be extended from the west lot line. <br />Refer to Exhibits 11. 1, J-1 and J-2. staff has sketched access scenarios based on City <br />Engineer's report. E.xhibit I shows Garden Lane realigned extended to west boundary (to <br />meet Lot 3 west lot line), J-1 shows a private road outlot with future extension to west along <br />with sewer easement. Lot 3 is defined as a back lot with sewer and access provided in 30'