Zoning File #2204 <br />January 14, 1997 <br />Page 4 <br />Grading/Drainage <br />Applicant's grading plan proposes a retention pond within Lot 1 to maintain and treat runoff from <br />development of Lots 1 and 2. The plan provides for a 20’ easement over drainageway that leads to <br />retention pond as requested by engineer (Exhibit G). Note drainage from culvert beneath road flows <br />to the northwest at the north side of roadway and to the southeast to the south side through Lot 5. <br />Drainage does not all flow to the south through Lot 5 as originally assumed in the sketch plan <br />review. <br />The City will ask for a detailed grading plan witli the development of Lot 5 as it relates to both site <br />drainage and driveway. The City Engineer shall review tlie grading plan and size of culvert to be <br />used where drive encroaches drainageway. <br />Private Road <br />Review Exhibit D, Planning Commission Members agreed that the existing drive and amenities <br />should be preserved as much as possible when applying the code standards for an upgraded private <br />roadway at a 24' width. Exhibit G, the Engineer's report and the Long Lake Asst. Fire Chiefs review <br />comments provide alternatives for tiie required upgrade. As for the entrance monuments, the City <br />Engineer recommends that the monuments be relocated to provide a 24' wide opening. In the Asst. <br />Fire Chiefs report, he recommends that the roadway for a distance of 100' west of the entrance <br />monuments be upgraded to a 28' width to allow emergency vehicles to park to one side while another <br />vehicle could freely pass. Both ask that the existing turn at the west end of the retaining w'all be <br />upgraded to facilitate the turning of emergency vehicles. This is now show n on your preliminary <br />plan. The City Engineer has asked that the roadway in between the retaining walls for 500' be <br />expanded to 22’ with curbing. This can be accomplished within the 24' width that exists between <br />retaining walls. <br />Staff also recommends that the cul-de-sac be staked so that staff can determine what trees would <br />need to be removed. There may be a need to adjust location of cul-de-sac to minimize tree removal. <br />Both the Fire Department and the City Engineer recommend the drive be upgraded to a 24' minimum <br />width and a combination of curbing and ditching can be 'vorked out in order to preserve as many of <br />the existing plantings adjacent to the roadway. <br />As already noted above, there is no future extension road leading from the north to the Fullerton <br />property. The cul-de-sac will be approved at a 1,600' length with a potential of 8 possibly 9 <br />residential units to be ser\ed. Lot 4 could be subdivided in the future. Topography and septic <br />limitations will prohibit future subdivision of Lots 1 and 2. Lot 3 with the 30 year covenant that <br />restricts construction within the southwest lakeshore yard will also prohibit future subdivision.
The URL can be used to link to this page
Your browser does not support the video tag.