Laserfiche WebLink
r <br />Driveway Acccss/Oullot A: <br />The City Fire Marshal and Long Lake Fire Department are reviewing the individual access for each <br />lot. The Fire Marshal and Fire Department are being asked to comment on the driveway <br />length/width and ability to turn emergency vehicles on each lot. It is likely that a circular driveway <br />will be required for each lot. A detailed grading plan and driveway construction plan will require <br />further engineering review. The City Engineer has recommended each driveway be designed to not <br />exceed a 10% grade. <br />Outlot A would be commonly owned as an access outlot for the driveway. The City’s front lot/back <br />lot standards require a minimum width of access outlets to be 30’ to accommodate drainage, snow <br />removal and screening without encroaching on neighboring properties. Outlot A is 110 ’ wide <br />meeting the 30’ requirement. Staff does not believe additional screening to the driveway will be <br />required since the property is heavily wooded. Some existing trees will be required to be removed to <br />accommodate a wider road surface and grading improvements to reduce driveway slope. <br />Easements and Covenants: <br />1 . Standard drainage and utility easements shall be dedicated on the final plat 10 ’ along the exterior <br />property lines. Ten-foot drainage and utility easements along the . A drainage and utility <br />easement 5 ’ either side of the boundary between Outlot A and Lot 12 shall be granted. <br />2. The delineated wetland in the north and west quadrant of Lot 1 shall be subject to a protective <br />covenant filed in the chain of title of the affected property, as an advisory to property owner and <br />future owners that said wetland is subject to WCA regulation and/or U.S. Army Corps of Engineers <br />jurisdiction. <br />3. Covenants shall be filed on the chain of title for each lot as an advisory to future property owners <br />that a primary and secondary drainfield site exist on the property and are protected. <br />Staff Recommendation: <br />Staff recommends approval of the preliminary plat and a wetland alteration variance for the shared <br />driveway based on the following findings: <br />1. <br />2. <br />3. <br />The layout of the lots meets the Zoning Code requirements for a fronl1)ack lot subdivision. <br />The proposed use of the land is consistent w ith the intent of the Comprehensive Plan. <br />The variance for the wetland crossing is justified based on the fact the w etland crossing is <br />required for access and the access minimizes impact on the wetland and buffer area. <br />4. Each lot has demonstrated two septic sites for each lot meeting local and state standards. <br />; <br />trp <br />#02-2139 Bo)cr Building Corp <br />3320 Watertown Road <br />SiMhilioo <br />Odote 11,2002 <br />Ri«e3or4