Laserfiche WebLink
Section 11.03, Subd. 2, Definition 24* "Lot Area, Minimuin"'Each lot shall contain the minimum <br />area required for each proposed lot as prescribed in the he mng Chapter of the City Code. In rural <br />zones not served by sanitary sewer, each lot must contain a minimum of two acres of contiguous dry <br />buildable land exclusive of wetlands, public and private rights-of-way. All rural lots must comply <br />with the City’s on-site septic system provisions of the City Code. <br />Subdivision Standards: <br />The general site plan meets all requirements for a front lot/ back lot subdivision. Back lots are <br />defined as “a lot typically separated from a public or private road by another lot and which gains <br />access to the public or private road via a narrow corridor. Such a separated lot is considered to be a <br />back lot when the corridor is platted as an outlot..” The special requirements for a front lot/back lot <br />division w the back lot (Lot 1), because the property does not have direct access to a road, must <br />meet a minimum of 150% of the minimum lot standards in the zoning district, in this case Lot 1 must <br />have a minimum lot size of 3 acres, and a principal building shall meet a minimum setback 150% of <br />the distrit^ standard. The lot is in the RR-1B district, which requires a minimum lot size of 2 acres. <br />Setbacks in the district are 50 front and rear yard, and 30 ’ for the side yard. <br />Back lots are required to have a driveway access a minimum of 30 ’ in width. The shared driveway <br />access meets the minimum requirements. Outlot A is much wider than 30 ’ at the road. This was <br />done to all.->w the driveway approach to be located at the highest point to provide the best site lines <br />for the drive vay. <br />Septic Review: <br />Each lot has demonsUated two septic sites for each lot meeting local and state standards. Matt <br />Bolterman, On-Site Systems Manager, has approved the designs that were submitted. <br />Wetlands: <br />The surveyed area noted above reflects the recent wetland delineation. The wetlands on Lot 1 and <br />Lot 2 are City protected. There will be some impact on wetlands by this development. Air photos <br />indicate the access has been through the wetlands for many years. This driveway access is ver> <br />nanow and may require widening. The Fire Code requires a minimum 20 ’ driveway access, <br />including the portion that crosses the wetland. If that impact does occur the WCA guidelines would <br />suggest that additional wetland area be created on the propert>. A variance will need to be granted <br />to allow access to go thru the wetlands. <br />i0}*3i)9 Bo)tr BtiiMinf Cotp <br />SiMivitiM <br />October 11,1002 <br />rai(2or4 <br />I