07-05-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1180 Mooney Lake Drive - 25-118-23-41-0016
>
Septic
>
07-05-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:06 PM
Creation date
10/1/2021 11:17:17 AM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Mooney Lake
Street Type
Drive
Address
1180 Mooney Lake Drive
Document Type
Septic
PIN
2511823410016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,.. , v, , .v i �. aan❑ LII �. mouna <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.p0 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 Iclean out Et valve box assemblies <br />TO ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />93:11 <br />upslope ratio 10 ft. upslope berm <br />sideslope 11 ft. sideslope berms <br />downslope 20 ft, downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope berm [E]t <br />I 1.0 Clean sand lift <br />2_7 fjFDep�th to Limiting <br />Limiting Condition — —b-- <br />Absorption Width <br />berm DTI <br />12" cover on sides <br />(6" loamy cap 8c 6" topsoil <br />Mote: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Wdthis measured downhill from the upslope edge of the Aed. <br />Rock Bed: 21.0 yd or*1.4= 29 ton 6 inches under pipe <br />Mound Sand: 105 yd or *1.4= 147 ton calculation based on 3:114:1 slope from top of rockbe, <br />Loamy Cap: 65 yd or "1.4= 91 ton 6" deep <br />Topsoil: 76 yd or *1.4= 106 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />118p Mooney Lake Drive <br />❑ WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds:. out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD , RD _, NE _. Protected wetland _. <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure se 10' to bed, tank Et sewer line. (else sewer line > 12" below) <br />Sewer line Et baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2,,in 8') <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />