My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-05-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1180 Mooney Lake Drive - 25-118-23-41-0016
>
Septic
>
07-05-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:06 PM
Creation date
10/1/2021 11:17:17 AM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Mooney Lake
Street Type
Drive
Address
1180 Mooney Lake Drive
Document Type
Septic
PIN
2511823410016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i i. .....,...,,.,rte <br />Individual slope ratios give BERM widths (topsoil beyond rockbed) of: <br />9)M <br />upslope ratio 10 ft. upslope berm <br />M sideslope 11 ft. sideslope berms <br />1) downslope 20 ft. downslope berm <br />Overall Dimensions: 10.0 ft, wide by 63.0 ft. long Rock bed <br />40 ft. wide by F85 ft. long Mound footprint <br />4" inspection pipe <br />r— 18" cover on top <br />U gslotae berm 1 10 <br />1.q Il Clean sand lift <br />_ 2,7 Depth to Limiting <br />Limning Condition ^—-------------_— <br />Absoration Width <br />berm 1 20 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />27.0 <br />Note: <br />For 4 to 1% slopes, .46soration Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the ,fed. <br />Rock Bed: <br />10.0 ft. by 63.0 ft. by ©inches under pipe, plus 20% gives 21 yd' or *1,4= 29 ton <br />sa) Mound Sand: (note: volume is based on 3:1/4:1 slope from top of rockbed, Exchange sand for loamy cap if desired) <br />19.0 up + 32.3 downslope + 6.9 ends + 29.2 under rack = 105 yds or "1.4= 147 ton <br />plus 20% <br />Loamy Cap: <br />=ft. by =ft. 6" deep, plus 20% gives <br />3o) Topsoil: <br />40 ft. by F 85 ft. 6" deep, plus 20% gives <br />F–&5—]yd' or *1.4= =ton <br />76 yd' or *1.4= 106 ton <br />accordance with all applicable ordinances, rules and laws. <br />Rusty olson's Soil 8t Perc <br />Signature Company <br />Installer Summary <br />810 7/5/2018 <br />License# Date <br />2250 gallon Septic tank (minimum) Tank options: none <br />:)Uk larger Lank wrtn muwpie comps sanKs <br />1300 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM 56 ft. of head, Pump required <br />9.8 linch swing on Demand float which translates to roughly 5.9 inches of float tether length <br />if time dosing is required e-> 7 minutes ON time ft ®hours OFF time <br />22 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />25 linches from bottom of tank to "Hi Level Alarm" or 35 inches to "Hi levet alarm" if time dosed <br />368 ft. of 2.0 inch supply line with end feed manifold connection <br />--177 (Tip: "top feed' manifold to control drainback) <br />
The URL can be used to link to this page
Your browser does not support the video tag.