Laserfiche WebLink
FILE #LA 20-000003 <br />February 18, 2020 <br />Page 2 of 4 <br /> <br />The Planning Commission should discuss if allowing flexibility to allow the existing 3 property <br />to continue to share a driveway off a new cul-de-sac would be supported. The alternative <br />would be to extend the road to the south, across long lake creek. <br />Parks/ Trails. The plans do not suggest any interior sidewalks or trails through the development. <br />The plans also do not show any proposed parkland dedication. The Comprehensive Plan does <br />not identify the need for additional park land on this property; it is anticipated that park <br />dedication will be satisfied by a cash donation for the 2 new lots. <br /> <br />Utilities. <br />The property is in the Metropolitan Urban Service Area (MUSA); the applicant proposes <br />establishing septic systems. While the property is within the MUSA boundary, there is no <br />infrastructure currently in place which will allow this property to connect to the sanitary sewer <br />system. (Sec. 82-224 only requires connection when the system is “reasonable accessible”.) The <br />two new lots have been tested but Olsons Septic Testing and each lot show 2 septic areas shown <br />on the sketch plan. Water will be furnished by individual wells. <br /> <br />The City Engineer provided comments recommending the applicant explore installing a low <br />pressure system which would allow them to connect to the municipal sanitary sewer. This would <br />require the applicant to obtain easements across private properties. <br /> <br />The roads and all utilities will be installed by the developer. This project will trigger stormwater <br />management rules of the MCWD. Additional improvements including ponding, ditches, and <br />curbing may be required. The applicant has been advised to visit with the watershed district <br />early in the subdivision design process. <br /> <br />Lots <br />The property is located within the LR-1A Zoning district. The three new proposed lots must have <br />a minimum of 2 acres in size and 200 feet of defined width. As shown on the sketch plan all 3 <br />lots appears to meet the minimum size requirement, though surface areas below the ordinary <br />high water mark of any surface water or wetlands or floodplain areas may not be used in order <br />to meet any portion of the minimum lot area requirements, and may impact Lot 2. <br /> <br /> <br /> Area (Gross) Width Width @Co. Rd 6 <br />Lot 1 3.49 536’ 565’ <br />Lot 2 17.20 225’ N/A <br />Lot 3 3.04 497 145* <br />• Area for Dry-buildable not identifies at this time. <br /> <br />Lot 3 is considered a corner lot with the front yard identified as the shortest distance abutting a <br />road. Staff supports establishing the front yard of lot 3 along the new road, meeting the width <br />requirements. <br /> <br />The OHWL elevation for Long Lake (944.3) is not identified on the survey and should be verified.. <br />Because Long Lake Creek feeds into the lake in a close proximity to the project there is a chance <br />the OHWL touches the property. This could possibly create a lakeshore lot along Lot 2 and/or