Laserfiche WebLink
210 OFFICE <br /> I McGUIRE RESIDENCE I <br /> HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES <br /> ROOM: 210 OFFICE j 1HEIGHT: 8.5 I <br /> FLOOR 2 1 !AREA: 178 VOLUME:) 1,513 <br /> OCCUPANTS: 0 1 I <br /> HEAT LOSS _ I <br /> ELEMENT AREA X MULTIPLIER = BTU/HR <br /> ROOF 1 178 S.F 2.21 Btu/Hr/S.F1 • 392_ <br /> DOORS 1 0 " 57' " 1 - <br /> WINDOWS 30 " 57 " 1,710 <br /> WALLS 59 5 2951 <br /> FOUNDATION 0 7.5 " - <br /> INFILTRATION* 6 CFM 102.6 Btu/Hr/CFM 647 <br /> 1 TOTAL: 3,043 <br /> VENTILATION** 0 CFM 102.6 Btu/Hr/CFM - <br /> I TOTAL 3,043 <br /> 1 L <br /> HEAT GAIN SENS. (LATENT TOTAL <br /> ROOF , 178 S.F. 0.92 Btu/Hr/S.F. 164 164 <br /> DOORS 1S &W 0 100 " 1 - - <br /> DOORS N&E 0 I 91 " I - - <br /> WINDOWS S&W 0 " 1001 " - - <br /> WINDOWS N 309 " <br /> I i 270 270 <br /> WINDOWS E 0 60 " - - <br /> WALLS !S&W 0 " j 1.91 - - <br /> WALLS N 59 1" j 0.8 i 1 I 47 47 <br /> WALLS E 0 1 0.8 " - - <br /> LIGHTS 1 178 1" 3.415 *** r 608 608 <br /> EQUIPMENT 0 KW 3415fBtu/kw - i ! - <br /> OCCUPANTS I 0 **** C 300/300! ! - I - - <br /> INFILTRATION 6 CFM 1 16/25 Btu/hr/CFM 101 j 158 258 <br /> I 1 I ; ITOTAL: 1,190 158 1,347 <br /> VENTILATION 0 1CFM 1 16/25-Btu/hr/CFM 1 ( - ! - - <br /> 1 I I !TOTAL: 1,190 158 I 1,347 <br /> NOTES: 1 <br /> I 1 _ <br /> Infiltration based on 1/4 air changes per hour 1 <br /> ***Lighting heat gain based on 1 watt per square foot 1 <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry j 1 <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load-based on light activity unless noted otherwise! <br /> Page 1 <br />