Laserfiche WebLink
209 BATHROOM <br /> 1 1 McGUIRE RESIDENCE 1 1 <br /> 1 HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES <br /> ROOM: 1209 MASTER BATHROOM 1 .HEIGHT: 1 8.5 <br /> FLOOR 1 21 1 'AREA: 1247 VOLUME: 2,100 <br /> OCCUPANTS: 0 I _ <br /> 1HEAT LOSS <br /> ELEMENT AREA X MULTIPLIER = BTU/HR <br /> ROOF 1 , 247 1S.F 2.2 Btu/Hr/S.FI 543 <br /> DOORS 1 I 0 57 " - <br /> WINDOWS 48 " 57 2,736 <br /> WALLS 1 114 " 5 " 570 <br /> FOUNDATION 0 7.5 " 1 - <br /> INFILTRATION* 9 CFM 102.6 Btu/Hr/CFM 1 1 898 <br /> 1 i j !TOTAL: 4,747 <br /> VENTILATION** 494 ;CFM j 102.61Btu/Hr/CFM 50,684 <br /> 1 TOTAL 55,431 <br /> 1 - <br /> 1 HEAT GAIN 1SENS. LATENT TOTAL <br /> ROOF 1 1 247 S.F. 0.92 Btu/Hr/S.F. 1 227 I 227 <br /> DOORS 'S&W 0 i 100 - - <br /> DOORS 1 N&E 0 " 91 " I j - I - <br /> I <br /> WINDOWS S&W 0 " 1001 " 1 - - <br /> WINDOWS N 48 " 91 " 1 432 432 <br /> WINDOWS E 1 0 601 " j - 1 - <br /> WALLS 1 S&W 0 I" 1.91 " - - <br /> WALLS IN 114 " 1 0.81 91 1 91 <br /> WALLS I E 0 1 0.81 " j - j - <br /> LIGHTS I 247 1" i 3.4151*** 844 844 <br /> EQUIPMENT 0 1KW 1 34151Btu/kw - I - <br /> OCCUPANTS 0 '"** 300/3001 ` 1 <br /> I ! � - <br /> i - <br /> INFILTRATION 9 IC FM 16/251Btu/hr/CFM `' j 140 219 359 <br /> 1 <br /> (TOTAL: 1,734 219 1,953 <br /> VENTILATION 1 494 1CFM 16/251Btu/hr/CFM I 7,904 12,350 20,254 <br /> 1 ;TOTAL: l 9,638 12,569 22,207 <br /> NOTES: <br /> Infiltration based on 1/4 air changes per hour j <br /> ***Lighting heat gain based on 1 watt per square foot 1 <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry 1 <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load-based on light activity unless noted otherwise. j <br /> Page 1 <br />