Laserfiche WebLink
211 BATHROOM <br /> McGUIRE RESIDENCE 1 <br /> I HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES I <br /> ROOM: 211 BATHROOM ! , , <br /> !HEIGHT: 8.5 j <br /> FLOOR I 21 1 I , ;AREA: 1 132 'VOLUME: 1,122 <br /> OCCUPANTS: 10 1 <br /> j C1 1 <br /> 1 HEAT LOSS 1 1 <br /> ELEMENT AREA! X MULTIPLIER 1= BTU/HR <br /> ROOF 1 132 S.F j 2.21Btu/Hr/S.FI 290 ' <br /> DOORS ; 0 i" 571 " I - <br /> WINDOWS 18 " 57 " I 1 1,026 <br /> WALLS 1 33 !" 5 " ! 165 <br /> FOUNDATION 0 ! j 7.5 " I - <br /> INFILTRATION* 5 rCFM CFM 102.6 Btu/Hr/CFM 480 <br /> !TOTAL: 1,961 <br /> VENTILATION** 264 CFM 102.6 Btu/Hr/CFM 1 27,086 <br /> : ! !TOTAL 29,047 <br /> i I 1 t, <br /> HEAT GAIN } ISENS. LATENT TOTAL <br /> ROOFROOF 1 132 S.F. 0.921Btu/Hr/S.F. 121 121 <br /> DOORS S&W 0 " 100 " I 1 J - - <br /> DOORS IN&E 0 I" 91 - ! j - <br /> WINDOWS S&W 0 �" 1001 " I - - <br /> WINDOWS N 18 I" 91 " I 1 162 162 <br /> WINDOWS E 0 1 1 601 " ii - - <br /> WALLS IS&W 1 0 1.91 " 1 - - <br /> WALLS N 33 1" 0.81 I 26 26 <br /> WALLS jE 0 0.81 I - I 1 - <br /> LIGHTS i 132 I" 3.4151*** 451 451 <br /> EQUIPMENT 0 1KW 3415!Btu/kw - - <br /> OCCUPANTS 0 !**** I 300/30011 - - - <br /> i <br /> INFILTRATION 5 ;CFM 16/251Btu/hr/CFM 75 !. 117 I 192 <br /> 1 !TOTAL: 1 835 117 1 952 <br /> VENTILATION ; 264 ICFM I 16/251Btu/hr/CFM 1 1 4,224 6,6001 10,824 <br /> j 1 !TOTAL: 5,059 I 6,717 I 11,776 <br /> NOTES: <br /> Infiltration based on 1/4 air changes per hour <br /> ***Lighting heat gain based on 1 watt per square foot <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry <br /> "—Occupants normally in continuous use of area <br /> Sensible and Latent load-based on light activity unless noted otherwisel <br /> Page 1 <br />