H.V.A.C. Calculations
Orono
>
Property Files
>
Street Address
>
W
>
Woodhill Road
>
315 Woodhill Road - 02-117-23-13-0008
>
Misc
>
H.V.A.C. Calculations
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:06:29 PM
Creation date
2/27/2020 9:05:24 AM
Metadata
Fields
Template:
x Address Old
House Number
315
Street Name
Woodhill
Street Type
Road
Address
315 Woodhill Rd
Document Type
Misc
PIN
0211723130008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
103 OFFICE <br /> I ; 1 McGUIRE RESIDENCE <br /> I HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES 1 <br /> ROOM: 1103 OFFICE I !HEIGHT: j 8.5 <br /> FLOOR j 11 I 1 AREA: 1 486 (VOLUME:, 4,131 <br /> OCCUPANTS: '1 <br /> ',HEAT LOSS <br /> ELEMENT I AREAI X MULTIPLIER ;= j BTU/HR <br /> ROOF j 0 1S.F 2.21 Btu/Hr/S.FIl - ! <br /> DOORS I 0 l" { 571 I - <br /> WINDOWS I 150 ," 57 " 1 8,550 <br /> WALLS 386 " 5 " � 1,930 <br /> FOUNDATION 0 ! 7.5 " 1 - <br /> INFILTRATION* 17 (CFM 102.61Btu/Hr/CFM 1,766 <br /> VENTILATION** 20 CFM 102.61Btu/Hr/CFM , I 2,052 j <br /> !TOTAL 1 I 14,298 r <br /> l HEAT GAIN ISENS. LATENT TOTAL <br /> I <br /> ROOF I 0 S.F. 1 0.921Btu/Hr/S.F. - - <br /> DOORS IS&W 1 0 I" 1001 " 1 - - <br /> DOORS jN&E 0 " 91- " - - <br /> WINDOWS S&W 50 ," 1001 " 5,000 5,000 <br /> WINDOWS N 50 1" 91 " 450 450 <br /> WINDOWS E { 50 6011 3,000 1 3,000 <br /> WALLS I S&W 103 1.91 " 1 I 196 196 <br /> WALLS N 283 j 0.81 '' 1 226 226 <br /> WALLS jE j 0 0.81 - , - <br /> LIGHTS 486 1 3.4151*** 1 1,660 i �j 1,660 <br /> EQUIPMENT 1 KW 34151Btu/kw I 3,415 j 1 3,415 <br /> OCCUPANTS j 1 1**'* 300/3001 j 1 300 j 300 ! 600 <br /> INFILTRATION 1 17 !CFH 0.3/0.41Btu/hr/CFH 5 J 71 12 <br /> VENTILATION 1 20 ;CFM 16/251-Btu/hr/CFM I 320 j 500 1 820 <br /> I ,TOTAL: ! 14,572 I 807 I 15,379 <br /> NOTES: ! <br /> Infiltration based on 1/4 air exchange per hour+A9 <br /> *** Lighting heat gain based on 1 watt per square foot ] j <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load- based on light activity unless noted otherwise <br /> Page 1 <br />