Laserfiche WebLink
102 GALLERY <br /> I j McGUIRE RESIDENCE <br /> HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES <br /> ROOM: 102 GALLERY I1 HEIGHT: T 8.5 <br /> FLOOR 1 , ! ! j AREA: 624 VOLUME:1 5,304 <br /> OCCUPANTS: '2 I ' <br /> HEAT LOSS <br /> ELEMENT AREA1 X MULTIPLIER 1= BTU/HR <br /> ROOF 0 S.F i 2.21 Btu/Hr/S.Fj - <br /> COORS 0 I" 571 " I I - <br /> WINDOWS I 0 57 " 1 - ! <br /> WALLS 1 518 I" j 5 " I 2,590 <br /> FOUNDATION I 624 7.5 1 4,680 <br /> INFILTRATION* 0 CFM 102.6 Btu/Hr/CFM 1 - ' <br /> I <br /> VENTILATION** 40 !CFM j 102.6 Btu/Hr/CFM 4,104 <br /> 1 TOTAL 11,374 <br /> 1 <br /> HEAT GAIN SENS. LATENT TOTAL <br /> ROOF I 0 S.F. 0.92 Btu/Hr/S.F. - - <br /> i <br /> DOORS S&W 0 1001 " 1 - - <br /> DOORS N&E 0 " 91 " ( I - - <br /> WINDOWS S&W 0 " 1001 - - <br /> WINDOWS N 1 0 " 91 " 1 - 1 1 - <br /> WINDOWS E 1 0 601 - I - <br /> WALLS I S&W 164 i" 1.91 " 312 1 312 <br /> WALLS IN 0 1" 0.81 " j - <br /> WALLS 'E 0 0.81 " j - I - <br /> LIGHTS j I 624 1" 3.4151*** 2,131 2,131 <br /> EQUIPMENT ! 0 1KW 1 34151Btu/kw j - 1 - <br /> OCCUPANTS 2 **** ! 300/3001 600 600 '; 1,200 <br /> INFILTRATION 0 ]CFH 16/251Btu/hr/CFM - - 1 - <br /> VENTILATION 40 CFM 16/251Btu/hr/CFM 640 1,000 1,640 <br /> TOTAL: 3,683 J 1,600 1 5,283 <br /> NOTES: ! ii <br /> Infiltration based on 1/4 air changes per hour 1 <br /> ***Lighting heat gain based on 1 watt per square foot 1 <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load-based on light activity unless noted otherwise] <br /> Page 1 <br />