Laserfiche WebLink
• <br /> ESR-1301 I Most Widely Accepted and Trusted Page 2 of 7 <br /> Rated Siding, Exterior Rated Siding—Sheathing is vertical or horizontal shiplap, or otherwise made <br /> intended to be installed in applications in accordance with waterproof. <br /> 2003/2006 IBC Section 2306.4.1, and 2009/2012 IBC 4.4 Component and Cladding Wind Pressure <br /> Section 2306.3. Capacity: <br /> P ty: <br /> 4.0 INSTALLATION Maximum allowable component and cladding wind loads <br /> 4.1 General: (wall, zone 5) for LP SmartSide® Precision Lap Siding and <br /> ® ® LP SmartSide® Precision Panel Siding based on a <br /> LP SmartSide® Precision Lap Siding and LP SmartSide® minimum fastener schedule, are provided in Tables 2 <br /> Precision Panel Siding must be installed in accordance through 5. Tables 2 and 3, for lap and panel siding, <br /> with the manufacturer's published installation instructions <br /> (titled Application Instructions LP SmartSide® Precision respectively, are based on full fastener penetration into the <br /> Lap LP SmartSide®Precision Panel Siding) and this report. wall studs, i.e., fastener penetration = fastener length - <br /> In the event of conflicts, this report governs. A copy of the siding thickness. Tables 4 and 5, for lap and panel siding, <br /> manufacturers installation instructions must be on the respectively, are based on a minimum fastener penetration <br /> jobsite at all times during installation. into the wall studs of 1 /z inches. <br /> LP SmartSide® Precision Lap Siding and LP SmartSide® 5.0 CONDITIONS OF USE <br /> Precision Panel Siding must be installed with an approved The LP SmartSide® Precision Lap Siding and LP <br /> water-resistive barrier as required by the applicable code. SmartSide® Precision Panel Siding described in this report <br /> Openings in, penetrations through, and terminations of the comply with, or are suitable alternatives to what is <br /> LP SmartSide® Precision Lap Siding and LP SmartSide® specified in, those codes listed in Section 1.0 of this report, <br /> Precision Panel Siding are outside the scope of this report subject to the following conditions: <br /> and must be specifically approved by the code official in 5.1 LP SmartSide Precision Lap Siding must not be <br /> accordance with the applicable code. used to satisfy the bracing requirements specified in <br /> Unless otherwise noted in this report, fasteners and the code. <br /> fastener spacing must be as noted in the applicable code. 5.2 LP SmartSide Precision Panel Siding—Sheathing, <br /> 4.2 LP SmartSide®Precision Lap Siding: when installed as set forth in this report, may be used <br /> LP SmartSide® Precision Lap Siding must be attached to as method 3 bracing specified in Section 2308.9 of <br /> framing members spaced a maximum of 16 inches the IBC and Section R602.10 of the IRC. <br /> (406 mm) on center for 3/6 category siding and a maximum 5.3 In areas where seismic analysis is required by the <br /> of 24 inches(610 mm)on center for'/16 category siding. applicable code, the applicable code requirements for <br /> ® wood structural panel shear walls must be consulted <br /> Self-aligning LP SmartSide® Precision Lap Siding is <br /> installed with nails placed at the top of the LP SmartSide® for additional detailing requirements, restrictions <br /> Precision Lap Siding, 1/2 inch (13 mm) down from the concerning certain usages, required modifications to <br /> upper edge. Each successive course of lap siding must the allowable shear loads tabulated in this report, and <br /> rest on the back rabbet and must self-align at an overlap of additional inspection requirements. <br /> 13/16 inch (21 mm). 5.4 LP SmartSide® Precision Lap Siding and LP <br /> Nails must be of sufficient length to penetrate a minimum SmartSide® Precision Panel Siding must not be <br /> of 11/2 inches (38 mm) through the sheathing and into installed in contact with concrete or masonry. <br /> framing at each stud location. 5.5 LP SmartSide® Lap Siding and LP SmartSide® <br /> 4.3 LP SmartSide®Precision Panel Siding: Precision Panel Siding must be installed with a <br /> minimum 6 inches (152 mm) of clearance from <br /> LP SmartSide® Precision Panel Siding must be installed finished grade. <br /> with its long dimension oriented vertically. 5.6 When field cuts are made to LP SmartSide®Precision <br /> When LP SmartSide® Precision Panel Siding is applied Lap Siding and LP SmartSide® Precision Panel <br /> directly to the framing, the maximum spacing of the Siding, all exposed surfaces must be finished <br /> framing must be consistent with the span rating of the LP according to the paint or caulk/sealant manufacturers' <br /> SmartSide® Precision Panel Siding, which is identified on specifications. <br /> the panel's label. 5.7 LP SmartSide® Precision Lap Siding and LP <br /> Allowable loads for shearwalls sheathed with LP SmartSide® Precision Panel Siding are manufactured <br /> SmartSide® Precision Panel Siding—Sheathing are noted by Louisiana-Pacific Corporation in Hayward, <br /> in Table 1. Wisconsin (Mill No. 357); Newberry, Michigan <br /> Four-foot-by-8-foot (1219 mm by 2438 mm) LP (Mill No. 416); Tomahawk, Wisconsin (Mill No. 435); <br /> SmartSide® Precision Panel Siding—Sheathing installed and Two Harbors, Minnesota (Mill No. 399); under a <br /> vertically, directly to framing, with a single row of nails quality control program with inspections by ICC-ES. <br /> penetrating both laps, spaced 6 inches on center at panel 6.0 EVIDENCE SUBMITTED <br /> edges and 12 inches (305 mm) on center at intermediate Data in accordance with the ICC-ES Acceptance Criteria <br /> supports may be used to satisfy the wall bracing for Treated-engineered-wood Siding (AC321), dated <br /> requirements for conventional light frame construction October 2005. <br /> specified in the code for prescriptive construction. Install <br /> per code requirements for method 3 bracing with wood 7.0 IDENTIFICATION <br /> structural panels. LP SmartSide® Precision Lap Siding and LP SmartSide® <br /> All LP SmartSide® Precision Panel Siding joints must Precision Panel Siding must be labeled with the product <br /> occur at framing members and must be protected with a designation and the name of Louisiana-Pacific Corp. The <br /> continuous wood batt, approved caulking, flashing, or stamp shall provide the following information: <br />