My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00589 - siding
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0041 Willow Drive North - 33-118-23-44-0031
>
Permits/Inspections
>
2017 - 00589 - siding
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:51 PM
Creation date
2/10/2020 1:18:46 PM
Metadata
Fields
Template:
x Address Old
House Number
41
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
41 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823440031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ESR-1301 I Most Widely Accepted and Trusted Page 3 of 7 <br /> N. <br /> 1. Mill number. 4. Span rating. <br /> 2. The evaluation report number(ESR-1301). 5. Performance category (based on customary inch <br /> 3. Grade/exposure. fractions). <br /> TABLE 1—ALLOWABLE RACKING SHEAR(plf)FOR LP SmartSide®Precision PANEL SIDING—SHEATHING SHEAR WALLS <br /> WITH FRAMING OF DOUGLAS FIR–LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING1'2'3 <br /> PERFORMANCE MINIMUM PANELS APPLIED DIRECTLY TO FRAMING <br /> CATEGORY NAIL PENETRATION IN Nail Size(Common or Nail Spacing at Panel Edges <br /> FRAMING(inches) Galvanized (inches) <br /> Box) 6 4 3 24 <br /> 5/165'6180 270 350 450 <br /> 3/65,6 1 1/4 6d 200 300 390 510 <br /> 3/65.6 220 320 410 530 <br /> 11/2 8d <br /> 7/165 240 350 450 585 <br /> 19/325 15/6 10d 340 510 6654 870 <br /> For SI: 1 inch=25.4 mm, 1 plf= 14.6 N/m. <br /> 1For framing of other species: (a) Find specific gravity for species of lumber in AF & PA National Design Specification; (b) find shear value <br /> from table for nails size; c) multiply value by 0.82 for species with specific gravity greater than or equal to 0.42 but less than 0.49, or 0.65 for <br /> species with specific gravity less than 0.42. <br /> 2AIl panel edges must be backed with 2-inch nominal or wider framing. Panels must be installed with the long dimension oriented in the vertical <br /> direction. Space nails 6 inches o.c. along intermediate framing members for 3/6 category and 7/16 category panels installed on studs spaced <br /> 24 inches o.c. For other conditions and panel thicknesses,space nails 12 inches o.c.on intermediate supports. <br /> 3The values are for short-term loads due to wind or earthquake (133% increase) and must be reduced by 25 percent for normal duration of <br /> loading. <br /> °Framing at panel edges must be 3 inches nominal or wider and nails must be staggered where nails are spaced 2 inches o.c.,and where 10d <br /> nails having penetration into framing of more than 15/6 inches are spaced 3 inches, or less, o.c. Exception: Unless otherwise required, 2-inch <br /> nominal framing may be used where full nailing surface is available and nails are staggered. <br /> 5Except as noted in Footnote 7, panel thickness at point of nailing at panel edges determines applicable shear values, except that 3/6 category <br /> panels nailed at shiplap edges use shear values for 5/16 category panels, and /16 and 19/32 category panel sidings nailed at shiplap edges use <br /> shear values for 3/6 category panels. <br /> 6Shiplap edges must be double-nailed; one nail must be placed in the underlap and a second nail must be placed in the overlap at the nail <br /> spacing specified for the applicable shear value. <br /> 'Fasteners must not be installed in panel siding grooves in the field of the panel siding or when the panel siding grooves occur at cut edges of <br /> the panel siding. <br /> TABLE 2a—LAP SIDING-MAXIMUM NOMINAL(ALLOWABLE)COMPONENT AND CLADDING DESIGN WIND SPEED,Vas91'2 <br /> PERFORMANCE MAXIMUM WALL SIDING MAXIMUM MAXIMUM NOMINAL(ALLOWABLE)WIND <br /> CATEGORY STUD SPACING' WIDTH ALLOWABLE WIND SPEED,Vasd4(mph) <br /> (inches) (inches) PRESSURE Wind Exposure Category <br /> (psf) <br /> B C D <br /> 6 80 170 150 140 <br /> 3/6 16 8 79 170 150 140 <br /> 12 50 140 120 110 <br /> 6 80 170 150 140 <br /> 16 8 76 170 150 130 <br /> 12 49 140 120 110 <br /> 765 <br /> 6 71 170 145 130 <br /> 24 8 51 155 120 110 <br /> 12 32 110 90 90 <br /> For SI: 1 inch=25.4 mm, 1 psf=47.88 Pa, 1 mph= 1.6 kph. <br /> 10ne fastener per stud located 3A inch from the top edge of the siding. Each successive course of lap siding must overlap a minimum of <br /> 1 inch. Fastener must have a minimum head diameter of 0.297 inch, a minimum shaft diameter of 0.113 inch and a minimum length of <br /> 2.5 inches(8d box nail). <br /> 2Tabulated values assume full penetration of the fastener into the wall studs, i.e.,fastener penetration=fastener length–siding thickness. <br /> 3Wall studs must have a minimum specific gravity of 0.42. <br /> °Three-second-gust; based on wind pressures acting toward and away from building surfaces, at 30-feet height in Zone 5 with smallest <br /> effective area per Chapter 6 of ASCE 7-05,Section R301.2 of the 2009/2012 IRC, and Section 1609.1.1 of the 2009 IBC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.