Laserfiche WebLink
1 <br /> . G <br /> SFMD Fact Sheet INS-FACT 1999-11 <br /> November 1, 1999 <br /> Page 3 of 4 <br /> Additional requirements for UL 142 AST <br /> UL 142 above ground storage tanks are plain steel tanks that may be either single or double wall. <br /> These tanks are not constructed to be fire resistive and thus have requirements for separation between <br /> the tank and buildings and also between the tank and dispenser. <br /> This page covers the additional requirements for single and double wall <br /> plain steel UL 142 tanks.Note the separation required between the tank <br /> and buildings plus the separation required between tank and dispenser. <br /> 1. A maximum of three ASTs are allowed for dispensing at any single dispensing site.AST shall no; <br /> exceed 6,000 gallons individual capacity for Class I liquids (gasoline)and 10,000 gallons <br /> individual capacity for Class H liquids (diesel fuel). <br /> 2. ASTs shall be separated from the dispenser by at least 30 feet. <br /> Exceptions: <br /> 1. Operations not open to the public and for resort operations serving re?istered ?uests oniv. <br /> dispensing of Class I liquids from one AST of 560 gallons capacity or less may have the <br /> dispenser located on top of. or adjacent to, the AST. <br /> 2. Operations not open to the public and for resort operations serving registered Quests oniv, <br /> Cwo AST of 1,000 gallons individual canacity or less may <br /> dispensing of Class II liquids from <br /> have the dispenser located on too of. or adiacent to. the AST. <br /> 3. Tanks shall be located not less than 50 feet from the nearest side of a public way, property <br /> line, building, or combustible storage located on the same property. <br /> Exception: ASTs which are separated by 30 feet or more from the dispenser may reduce the <br /> distances between the AST and the public way, property line, building, or combustible storaQe <br /> to 30 feet. <br /> !. Fuel delivery shall be -om the top or the AST with the dispensing line equipped with an <br /> approved antisyphon system. <br /> 6. Dispensing lines between a diked area or_-\.ST and a dispenser shall be Tocated underground and <br /> shall be in an approved secondary containment piping system. <br /> 6. Dispensing lines shall have an approved normally closed solenoid valve at each dispenser below <br /> the impact valve. <br /> 7. Fill pipes between a diked area or AST and the fill pipe opening shall be located underground. <br /> The fill pipe shall also be equipped with manually operated mechanical shut-off valve located <br /> inside the diked area, but can be operated from outside the dike. <br /> 3. ASTs shall be provided with lightning protection in accordance with the National Fire Protection <br /> Association Standard 780 (1994 edition). <br /> 9. When required by the local fire chief,multiple AST installations shall be protected by an <br /> approved fire protection system. <br />