My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Above Ground Flammable/Combustible Liquids
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2687 Wayzata Boulevard West - 33-118-23-13-0002
>
Misc
>
Above Ground Flammable/Combustible Liquids
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:14 PM
Creation date
2/4/2020 12:58:58 PM
Metadata
Fields
Template:
x Address Old
House Number
2687
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2687 Wayzata Boulevard West
Document Type
Misc
PIN
3311823130002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SFMD Fact Sheet INS-FACT 1999-11 <br /> November 1,1999 <br /> Page 4 of 4 <br /> Additional requirements for 2-HOUR PROTECTED AST <br /> Fire resistive 2-hour protected above ground storage tanks usually include steel tanks that are double <br /> wall and encased in some form of protective insulation such as reinforced concrete.These tanks are <br /> constructed to be fire resistive and thus have reduced requirements for separation between the tank <br /> and buildings and also between the tank and dispenser. A plain steel tank(either single or double <br /> wall) is not a 2-hour protected tank and must instead be installed following the spacing requirements <br /> for UL 142 tanks found on page 3 of this information sheet. <br /> This page covers the additional requirements for double wall fire resistive <br /> 2-hour protected tanks.The separation distances given here apply only to this <br /> type of tank and do not apply for single or double wall plain steel tanks. <br /> 1. ASTs shall not exceed 12,000 gallons individual capacity or 43,000 gallons aggregate capacity at <br /> any one dispensing site. <br /> :. ASTs less than or equal to 6,000 gallons shall be located at least 1 feet from property nines that <br /> can be built upon, including opnosite sides of a public way. These ASTs shall also be located at <br /> least 5 'eet from buildings and the near side of a public way(see the table below) <br /> ASTs rezte;than 6.000 gallons shall be located at ;east `ee:from propene✓lines that Carl be <br /> built U-con. including opposite sides of a public way. These ASTs shall also be located at least =: <br /> fee:from buildings and the near side of a public way(see the table at the bottom of this nage). <br /> !. ASTs shall have overfill prevention that will provide notification at 3P'o I-- and automatically <br /> slob fuel flow at 90%. <br /> �. Disuensina devices can be installed on or adjacent to the AST. <br /> 6. nd.sluIlon devices shall be installed on the external piping when the piping e:.te nas below :he <br /> licuid level of the AST. <br /> 7. Fill openings shall have a spill container at least 5 gallon capacity. <br /> Minimum separation requirements for protected aboveground tanks <br /> Individual Tank i )Minimum distance from Minimum distance l�linimum <br /> Capacity property line which is or from the nearest side of distance <br /> (gallons) can be built upon, any public way or from between tanks <br /> including the opposite the nearest important <br /> side of a public way building on the same ! <br /> property <br /> Less than or equal' 115 feet 15 feet j feet <br /> to 6,000 <br /> i <br /> Greater than 6,000 25 feet 15 feet 3 feet <br />
The URL can be used to link to this page
Your browser does not support the video tag.