Laserfiche WebLink
n <br /> 333Bayview Avenue GEMC-FK1 KEYPAD <br /> Amityville,New York 64 DATA SHEET <br /> For Sales and Repairs,(800)0)645-9445 <br /> For Technical Service,(800)645-9440 <br /> Publicly traded on NASDAQ Symbol:NSSC <br /> 0 NAPCO 2010 W11910 09/10 <br /> DESCRIPTION through the two vertical elongated holes on the left side of <br /> The GEMINI 4 wire bus GEMC-FK1 keypad is compatible the case and into the box. If the box is visible when viewed <br /> with the NAPCO GEMINI CSeries Control panels. See from the front, adjust the keypad vertically and tighten the <br /> Installation instructions(WI1653)for more information. screws. Then, using hardware suitable for the mounting <br /> Note: Do not install classic Gemini"RP"series keypads or surface, add one or two screws at the right side of the <br /> Gemini "K Series" keypads within a Gemini C-Series sys- keypad case directly into the wall to ensure a secure <br /> tem. installation. Note: Do not over tighten the screws! Uneven <br /> walls may cause the keypad case to distort. <br /> Note: INDOOR/DRY LOCATION USE ONLY <br /> WIRING <br /> Connect the keypad wires to the control panel terminals <br /> shown in the table below. <br /> COLOR TERMINAL COMMENTS <br /> e WM RED 18 <br /> lo <br /> > 11110111 OEMWE BLACK 19 <br /> GREEN 20 <br /> " e 101 NED '°` YELLOW 21 <br /> COMMERCIAL SECURITY SYSTEM VIOLET* 13(+) Primary interface Trouble <br /> WHITE* 14(—) sounder <br /> "Cut and insulate wire if not used in Supplemental <br /> keypads(required for primary user interface). <br /> ELECTRICAL RATINGS <br /> Input Power: 12VDC nominal, 115mA maximum, 35mA if KEYPAD AS PRIMARY USER INTERFACE <br /> backlighting is disabled (cut jumpers W1,W2&W3). For primary user interface, mount frameable label 01343 <br /> Maximum Number of Fire Keypads: 7 adjacent to keypad. For keypad address and option jump- <br /> Maximum Number of Fire Keypads + Burglary Key- ers, see product label. <br /> pads: 15 <br /> PHYSICAL <br /> POWER RATINGS Dimensions: 5'/"x 4 V x 1"(WxHxD) <br /> GEMC-FK1 is powered by the Fire bus of the GEMC- <br /> Series motherboard, GEMC-12V2APS or an appropriately AGENCY LISTINGS <br /> rated UL Listed power limited power supply suitable for UL864 9th Edition: Commercial Fire <br /> Fire alarm service. Deduct these values from the system UL985: Household Fire Warning System Units <br /> standby current, as described in the control panel wiring NFPA 72 National Fire Alarm Code <br /> diagram. Security Industry Association (SIA) False Alarm Reduction <br /> Standard CP-01 <br /> MOUNTING THE KEYPAD CSFM: California State Fire Marshall (Pending) <br /> To open the case, insert a screwdriver into either slot at the FM Approval: (Pending) <br /> bottom and push up with a slight twisting motion to release NYCFD: NYC Fire Department(Pending) <br /> the retainer tab. Repeat for the other slot. Pull out at the <br /> bottom and lift off the two hooks at the top. ORDERING INFORMATION <br /> The keypad features a handy pull-up reference label. GEMC-FK1: LCD Fire Keypad for GEMC Combo System, <br /> Before mounting the keypad onto the wall, push the Sliding Red. <br /> Label Plate (with label and felt backing affixed and handle <br /> facing forward) down the guides at the rear of the keypad <br /> until it snaps into place. Once installed, the Sliding Label <br /> Plate cannot be removed without first removing the keypad <br /> from the wall. <br /> If installing onto a double-gang box, insert mounting screws 71 <br />