2012-00697 - fire alarm system
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2725 Wayzata Boulevard West - 33-118-23-13-0019
>
Permits/Inspections
>
2012-00697 - fire alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:35 PM
Creation date
2/3/2020 10:34:53 AM
Metadata
Fields
Template:
x Address Old
House Number
2725
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2725 Wayzata Boulevard West
Document Type
Permits/Inspections
PIN
3311823130019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-1114 <br /> n FWC-FSLC-SMK, FWC-FSLC-SMKALG, <br /> Nv o FWC-FSLC-HEAT, FWC-FSLC-SMK6B <br /> 333 Bayview Avenue & FWC-FSLC-SMK4B <br /> Amityville,New York 11701 <br /> For Sales and Repairs,(800)645-9445 DATA SHEET <br /> For Technical Service,(800)645-9440 <br /> Publicly traded on NASDAQ Symbol:NSSC <br /> ©NAPCO 2010 WI1928 09/10 <br /> ORDERING INFORMATION <br /> FWC-FSLC-SMK: Addressable SLC Photoelectric AGENCY LISTINGS <br /> Smoke Detector UL268: Smoke Detectors for Fire Alarm Signaling Sys- <br /> FWC-FSLC-SMKALG: Replacement head for the FWC- tems(FWC-FSLC-SMK, FWC-FSLC-SMK6B & FWC- <br /> FSLC-DUCT Photoelectric Analog Duct Detector (see FSLC-SMK4B) <br /> Wl1711). UL268A: Smoke Detectors for Duct Application (FWC- <br /> FWC-FSLC-HEAT: Addressable SLC Heat Detector FSLC-SMKALG replacement head for the FWC-FSLC- <br /> 135°F DUCT) <br /> FWC-FSLC-SMK6B: 6" Analog Smoke Detector (base UL521: Heat Detectors for Fire Protective Signaling Sys- <br /> only). tems (FWC-FSLC-HEAT) <br /> FWC-FSLC-SMK4B: FWC-FSLC-SMK6B - 6" Analog NFPA 72 National Fire Alarm Code <br /> Smoke Detector(base only). CSFM: California State Fire Marshall (Pending) <br /> Note: These sensors are compatible exclusively with fire FM Approval: (Pending) <br /> alarm control panels that utilize Napco's protocol, DCP. NYCFD: NYC Fire Department(Pending) <br /> For installation instructions, see Wl1709. <br /> SPECIFICATIONS <br /> CATEGORY FWC-FSLC-SM$ FWC-FSLC-SMKALG FWC-FSLC-HEAT FWC-F3LC-SM$6B FWC-FSLC-SM$4B <br /> Absolute Maximum <br /> Applied Voltage 39.5 VDC 41.0 VDC: 41.0 VDC 41.01'DC 41.0 VDC <br /> Operating Voltage <br /> u`t <br /> Range(%1111(S- `39.3 N� 24—40.7 VDC 24 40.7 VDC 24 VDC DC 24 40.7 VDC <br /> Sensitivity Range SEE CHART BFIX)W SEE CHART BELOW 572°C—65.5°C N/A N/A <br /> (135°F-1 MrPl, <br /> Current Consumption 390µA Typical 390µA Typical 350µA Typical v/ `/� <br /> (S•SC)formal Mode SWJAA Maxi,nurc 540µA Maximum 500µA Maxiroum <br /> Currrnt Consun Ion <br /> A <br /> (S-SC)l3'hen Polled 2mA 2mA 2mN/A ti/,A <br /> ,Alarm Current(S-SQ (See Base) (See Bast) (Sec Base) 8roA(Typical) 8roA(Typical) <br /> Remote LED Current (See Base) (See Bax) (See Base) 8nL.k(Typical) 8rnA(Typical), <br /> Device Type Code 88 Hex 88 Hex 98 Hex N/A <br /> _10'C-50°C _100C-- 500C -10°C-WC -1o'C-50°C .10°C--50°C <br /> Operating Temperature 1140F— 122T (140F— 1220E (14-F—1220I) (140F—122-F) 14°F 122°F <br /> UL listed temperature 00C—37.80C 0 C—3 r.8 C 0'C—47-C 00C-470E 00C_^-470C <br /> (320F-- 1000F) (32-F—100-F) 32°F--11 M (32°F— 115°F) (32°F—115°1-) <br /> Storage Temperature -2000--60°C -200C—600C -20°C--60'C -200C--60°C -20'C--OUT <br /> (4-F—140° 40F- 140° -40F 1400 (-4°F-- 140°F, (4-F^- 140'F) <br /> Test * N/A N/A <br /> Dimensions 3-15/16"DX1-1/2"14 3-15/16"DX1-1/2-H 3.15/16"DX1-9/16-H 5.7/6"DX15/32"H 4-1/8"DX 5/16"H <br /> Environment Indoor Use Only Indoor Use Onh* Indoor Use Only Indoor Use Only Indoor Use Only <br /> Visual Alarm/ <br /> Power Indicator <br /> Dual LED Dual I-ED Dual LED Set Sensor See Sensor <br /> Power <br /> Address Setting * N/A <br /> s=See Control Panel For proper address setting and testing procedure. <br /> SENSITIVITY RANGES <br /> VEL(K[TY rn FWC-FSLC-SMKALG(%/ft.) F%'C_FSLC-SMK(°./o/Et.) BOX_41OUNTING <br /> 300 .88-3.57 0.5- 3.80 BASE 3"-0 4'-0 4"-S <br /> 2000 .88-2-81 0.5-2.74 <br /> 4000 .88-2.52 0.5-2-68 FWC-FSLC-SMK6B YES YES YES <br /> FWC-FSLC-SMK4B YES NO NO <br /> (k_v <br />